Literature DB >> 21394621

Monitoring the microcirculation in the critically ill patient: reflectance spectroscopy.

Thomas W L Scheeren.   

Abstract

Entities:  

Mesh:

Year:  2011        PMID: 21394621      PMCID: PMC3098352          DOI: 10.1007/s00134-011-2197-1

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


× No keyword cloud information.
Dear Editor, I read with great interest and pleasure the excellent overview of the most common methods currently used to monitor the microcirculation by De Backer and colleagues [1]. The expertise of this group of authors with most of the methods described in their review of innumerable original publications was clearly evident. However, the section on reflectance spectroscopy is rather short, suggesting that they may lack in-depth practical experience with that specific method. In particular, the last sentence on recent developments in the technique is incorrect and needs to be explained more specifically. The first device using reflectance spectroscopy (EMPHO) was limited to perpendicular probes for mucosa measurements and was based on spectrophotometry only. Nevertheless, it has been used in numerous experimental and clinical studies performed by our group for assessing the effects of various factors and agents, such as positive airway pressure, intraabdominal pressure, hypercapnia, cardiopulmonary bypass, vasoactive drugs and anaesthetics, on the splanchnic microcirculation [for references, see the Electronic Supplementary Material (ESM)]. The latest development using reflectance spectroscopy is incorporated in the O2C (oxygen to see) device (Lea, Giessen, Germany). The technology of the O2C device is based on two physical principles: reflection spectroscopy and the laser Doppler technique. Compared to the EMPHO device, the O2C instrument integrates both techniques in a much smaller device because the rotating filter wheel has been replaced by a CCD-spectrometer and the xenon high-pressure lamp by a small light source optimised for fibre optics. Specific probes are used to introduce white light (wavelengths 500–800 nm) and laser light (wavelength 830 nm) simultaneously into the tissue. A part of the light spectrum is absorbed when the white light interacts with the erythrocytes, and this absorbed portion assumes the colour of the haemoglobin as a measure of its oxygen saturation. The laser light experiences a frequency displacement due to the moving erythrocytes (the so-called Doppler Shift), and this displacement is a measure of their velocity. The sum of all erythrocytes and their velocity is a measure of blood flow (volume flow) in the complex network of capillaries. With this device the following parameters can be measured simultaneously in tissue: the oxygen saturation of haemoglobin (μHbO2) at the venous end of the capillaries (the so-called “last meadow”); the regional amount of haemoglobin (rHb) in the micro-blood vessels as a measure of its blood volume and for capillary density; the velocity of the blood in microcirculation; the flow of blood in the microcirculation. The main advantage of this technology when assessing microvascular blood flow is that this combination of parameters allows the determination of regional oxygen consumption (rVO2) in the tissue as a direct measure of tissue viability. The metabolism may be a more important parameter than the heterogeneity of perfusion, which is considered to be a key to monitor sepsis (for details, see ESM). The method has been used clinically to assess the microvascular response in patients with septic shock [2], to monitor the effects of extreme anaemia [3] or flap viability [4] and to predict wound healing in burn injury [5]. In conclusion, the combination of reflection spectroscopy and laser Doppler (O2C) may offer a useful enlargement of the diagnostic tools available to the clinician for assessing microvascular blood flow and tissue oxygen consumption. Below is the link to the electronic supplementary material. Supplementary material 1 (DOC 112 kb)
  5 in total

1.  Microcirculatory monitoring of a Jehovah's Witness suffering from haemorrhagic shock.

Authors:  A Menzebach; C Mutz; T W L Scheeren
Journal:  Eur J Anaesthesiol       Date:  2008-01       Impact factor: 4.330

2.  Characterization of buccal microvascular response in patients with septic shock.

Authors:  Yasser Sakr; Veronika Gath; Janaina Oishi; Stefan Klinzing; Tim-Phillip Simon; Konrad Reinhart; Gernot Marx
Journal:  Eur J Anaesthesiol       Date:  2010-04       Impact factor: 4.330

3.  Results of monitoring fasciocutaneous, myocutaneous, osteocutaneous and perforator flaps: 4-year experience with 166 cases.

Authors:  F Hölzle; A Rau; D J Loeffelbein; T Mücke; M R Kesting; K-D Wolff
Journal:  Int J Oral Maxillofac Surg       Date:  2009-11-26       Impact factor: 2.789

4.  Cutaneous microcirculatory assessment of the burn wound is associated with depth of injury and predicts healing time.

Authors:  K M Merz; M Pfau; G Blumenstock; M Tenenhaus; H E Schaller; H O Rennekampff
Journal:  Burns       Date:  2009-10-25       Impact factor: 2.744

Review 5.  Monitoring the microcirculation in the critically ill patient: current methods and future approaches.

Authors:  Daniel De Backer; Gustavo Ospina-Tascon; Diamantino Salgado; Raphaël Favory; Jacques Creteur; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

  5 in total
  6 in total

Review 1.  From system to organ to cell: oxygenation and perfusion measurement in anesthesia and critical care.

Authors:  Patrick Schober; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2012-03-22       Impact factor: 2.502

Review 2.  Effects of impaired microvascular flow regulation on metabolism-perfusion matching and organ function.

Authors:  Tuhin K Roy; Timothy W Secomb
Journal:  Microcirculation       Date:  2020-12-21       Impact factor: 2.679

Review 3.  Optimal management of the critically ill: anaesthesia, monitoring, data capture, and point-of-care technological practices in ovine models of critical care.

Authors:  Saul Chemonges; Kiran Shekar; John-Paul Tung; Kimble R Dunster; Sara Diab; David Platts; Ryan P Watts; Shaun D Gregory; Samuel Foley; Gabriela Simonova; Charles McDonald; Rylan Hayes; Judith Bellpart; Daniel Timms; Michelle Chew; Yoke L Fung; Michael Toon; Marc O Maybauer; John F Fraser
Journal:  Biomed Res Int       Date:  2014-03-25       Impact factor: 3.411

Review 4.  Journal of Clinical Monitoring and Computing 2015 end of year summary: tissue oxygenation and microcirculation.

Authors:  T W L Scheeren
Journal:  J Clin Monit Comput       Date:  2016-02-20       Impact factor: 2.502

5.  Effect of bupivacaine and adjuvant drugs for regional anesthesia on nerve tissue oximetry and nerve blood flow.

Authors:  Thomas Wiesmann; Stefan Müller; Hans-Helge Müller; Hinnerk Wulf; Thorsten Steinfeldt
Journal:  J Pain Res       Date:  2018-01-23       Impact factor: 3.133

6.  Role of Combining Peripheral with Sublingual Perfusion on Evaluating Microcirculation and Predicting Prognosis in Patients with Septic Shock.

Authors:  Pan Pan; Da-Wei Liu; Long-Xiang Su; Huai-Wu He; Xiao-Ting Wang; Chao Yu
Journal:  Chin Med J (Engl)       Date:  2018-05-20       Impact factor: 2.628

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.