Literature DB >> 21388381

In vivo comparison of the optical clearing efficacy of optical clearing agents in human skin by quantifying permeability using optical coherence tomography.

Xiao Guo1, Zhouyi Guo, Huajiang Wei, Hongqin Yang, Yonghong He, Shusen Xie, Guoyong Wu, Xiaoyuan Deng, Qingliang Zhao, Lanquan Li.   

Abstract

The objective of this work is to quantify and compare the optical clearing efficacy of glucose, propylene glycol, glycerol solutions through the human skin tissue in vivo by calculating permeability coefficient of three solutions. Currently, the permeability coefficient of agent in tissues was extracted from optical coherence tomography (OCT) amplitude data mainly through the OCT signal slope and the OCT amplitude methods. In this study, we report the OCT attenuation coefficient method which is a relatively novel and rarely reported methodology to measure the permeability coefficient during the optical skin clearing procedure. The permeability coefficients for 40% propylene glycol, glucose and glycerol were (2.74 ± 0.05) × 10(-6) cm s(-1), (1.78 ± 0.04) × 10(-6) cm s(-1) and (1.67 ± 0.04) × 10(-6) cm s(-1), respectively. It could be clearly seen that the permeability coefficient of the 40% propylene glycol solution is higher than that of 40% glucose solution, and the permeability coefficient of the 40% glucose solution is higher than that of the 40% glycerol solution. These indicate 40% propylene glycol solution is more effective than others in the human skin in vivo. We then compare and prove consistency of optical clearing efficacy figured out by three different methods.
© 2011 The Authors. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21388381     DOI: 10.1111/j.1751-1097.2011.00908.x

Source DB:  PubMed          Journal:  Photochem Photobiol        ISSN: 0031-8655            Impact factor:   3.421


  4 in total

1.  Optical clearing based cellular-level 3D visualization of intact lymph node cortex.

Authors:  Eunjoo Song; Howon Seo; Kibaek Choe; Yoonha Hwang; Jinhyo Ahn; Soyeon Ahn; Pilhan Kim
Journal:  Biomed Opt Express       Date:  2015-09-28       Impact factor: 3.732

2.  Measurements of the thermal coefficient of optical attenuation at different depth regions of in vivo human skins using optical coherence tomography: a pilot study.

Authors:  Ya Su; X Steve Yao; Zhihong Li; Zhuo Meng; Tiegen Liu; Longzhi Wang
Journal:  Biomed Opt Express       Date:  2015-01-12       Impact factor: 3.732

3.  Investigating the optical clearing effects of 50% glycerol in ex vivo human skin by harmonic generation microscopy.

Authors:  Jia-Hong Lai; En-Yu Liao; Yi-Hua Liao; Chi-Kuang Sun
Journal:  Sci Rep       Date:  2021-01-11       Impact factor: 4.379

4.  Recent progress in tissue optical clearing.

Authors:  Dan Zhu; Kirill V Larin; Qingming Luo; Valery V Tuchin
Journal:  Laser Photon Rev       Date:  2013-02-05       Impact factor: 13.138

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.