Literature DB >> 21386139

Magnetic flux density reconstruction using interleaved partial Fourier acquisitions in MREIT.

Hee Myung Park1, Hyun Soo Nam2, Oh In Kwon2.   

Abstract

Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive modality to visualize the internal conductivity and/or current density of an electrically conductive object by the injection of current. In order to measure a magnetic flux density signal in MREIT, the phase difference approach in an interleaved encoding scheme cancels the systematic artifacts accumulated in phase signals and also reduces the random noise effect. However, it is important to reduce scan duration maintaining spatial resolution and sufficient contrast, in order to allow for practical in vivo implementation of MREIT. The purpose of this paper is to develop a coupled partial Fourier strategy in the interleaved sampling in order to reduce the total imaging time for an MREIT acquisition, whilst maintaining an SNR of the measured magnetic flux density comparable to what is achieved with complete k-space data. The proposed method uses two key steps: one is to update the magnetic flux density by updating the complex densities using the partially interleaved k-space data and the other is to fill in the missing k-space data iteratively using the updated background field inhomogeneity and magnetic flux density data. Results from numerical simulations and animal experiments demonstrate that the proposed method reduces considerably the scanning time and provides resolution of the recovered B(z) comparable to what is obtained from complete k-space data.

Entities:  

Mesh:

Year:  2011        PMID: 21386139     DOI: 10.1088/0031-9155/56/7/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Accelerating acquisition strategies for low-frequency conductivity imaging using MREIT.

Authors:  Yizhuang Song; Jin Keun Seo; Munish Chauhan; Aprinda Indahlastari; Neeta Ashok Kumar; Rosalind Sadleir
Journal:  Phys Med Biol       Date:  2018-02-13       Impact factor: 3.609

2.  Current density imaging using directly measured harmonic Bz data in MREIT.

Authors:  Chunjae Park; Oh In Kwon
Journal:  Comput Math Methods Med       Date:  2013-03-20       Impact factor: 2.238

3.  Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions.

Authors:  Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2013-08-27       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.