Accuracy of 20-MHz Doppler catheter coronary artery velocimetry for measurement of coronary blood flow velocity.

S Tadaoka1, M Kagiyama, O Hiramatsu, Y Ogasawara, K Tsujioka, Y Wada, T Sawayama, F Kajiya.   

Abstract

The accuracy of 20-MHz Doppler catheter coronary artery velocimetry (Millar Instruments) was evaluated by model experiments using a turntable and a flow tube. In the turntable experiments, the flow away from the catheter tip (away flow) was significantly lower than that toward the catheter (toward flow), but the measured velocities for both away and toward flows were always lower than the known velocities. Nevertheless, the blood velocities measured at a sampling point 4 mm from the catheter tip showed excellent correlation with the known velocities irrespective of flow direction. The shape of the FFT spectra of the Doppler shift frequency from blood was broadened, and the frequency corresponding to the known velocity was always close to the maximum Doppler shift frequency. We concluded that zero-cross detection of blood velocity by the 20-MHz pulsed Doppler catheter provides a reliable measure for evaluating relative velocity changes, although it underestimates the blood velocity.

Mesh:

Year:  1990        PMID: 2138509     DOI: 10.1002/ccd.1810190313

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  5 in total

1.  Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler.

Authors:  J Ge; R Erbel; J Zamorano; M Haude; P Kearney; G Görge; J Meyer
Journal:  Int J Card Imaging       Date:  1995-06

2.  Clinical methods to determine coronary flow and myocardial perfusion.

Authors:  M J Wolters-Geldof; V M Cats; A V Bruschke
Journal:  Int J Card Imaging       Date:  1997-04

3.  Velocity measurements with a new ultrasonic Doppler method independent of angle of incidence.

Authors:  Shigeru Akamatsu; Yuji Kondo; Shuji Dohi
Journal:  J Anesth       Date:  1996-06       Impact factor: 2.078

4.  Effects of distension of urinary bladder on coronary conduit and resistance vessels in hyperlipidemic patients.

Authors:  Tsung-Ming Lee; Sheng-Fang Su; Chang-Her Tsai
Journal:  Clin Cardiol       Date:  2002-10       Impact factor: 2.882

5.  Decreased mid-to-late diastolic decay of diastolic coronary artery flow velocity in pressure-overloaded left ventricular hypertrophy.

Authors:  S Tadaoka; A Kimura; T Yada; K Tsujioka; S Nezuo; T Sawayama; F Kajiya
Journal:  Heart Vessels       Date:  1993       Impact factor: 2.037