Literature DB >> 21383520

Effect of surface preparation on the bond strength of heat-polymerized denture base resin to commercially pure titanium and cobalt-chromium alloy.

Tomohiro Kawaguchi1, Hiroshi Shimizu, Lippo V J Lassila, Pekka K Vallittu, Yutaka Takahashi.   

Abstract

The aim of this study was to investigate the bond durability of heat-polymerized denture base resin to cast CP Ti and Co-Cr alloy. The alloy specimens were divided into five groups: 1) airborne-particle abraded with 50 µm alumina (SAND), 2) Rocatec tribochemical silica coating system (RO), 3) air-abraded followed by application of Epricord Opaque Primer (EP), 4) air-abraded followed by application of Super Bond C&B liquid (SB), 5) air-abraded followed by application of Alloy Primer (AL). Heat-polymerized denture resin was applied to the bonding area and polymerized according to the manufacturer's instructions. The halves of all specimens were thermocycled up to 10,000 cycles. Before thermocycling SB and AL showed significantly higher shear bond strengths than SAND, RO, EP for both metals. The shear bond strength of AL group after thermocycling was significantly higher than that of the other groups.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21383520     DOI: 10.4012/dmj.2010-089

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  6 in total

1.  Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy.

Authors:  Kohji Kamada; Yohsuke Taira; Tadateru Sumi; Takashi Sawase
Journal:  Odontology       Date:  2016-06-20       Impact factor: 2.634

2.  Effect of Fiber Laser Irradiation on the Shear Bond Strength between Acrylic Resin and Titanium.

Authors:  Fatih Mehmet Korkmaz; Selin Aycan
Journal:  Scanning       Date:  2019-09-03       Impact factor: 1.932

3.  Bond strength of locator housing attached to denture base resin secured with different retaining materials.

Authors:  Mohammadreza Nakhaei; Hossin Dashti; Atefe Baghbani; Zahra Ahmadi
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

4.  Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study.

Authors:  Minal Sanjay Kumthekar; Shivsagar Tewary; Pronob Kumar Sanyal
Journal:  J Indian Prosthodont Soc       Date:  2020-10-08

5.  Comparative evaluation of effect of metal primer and sandblasting on the shear bond strength between heat cured acrylic denture base resin and cobalt-chromium alloy: An in vitro study.

Authors:  Sandeep Kalra; Vishwas Kharsan; Nidhi Mangtani Kalra
Journal:  Contemp Clin Dent       Date:  2015 Jul-Sep

6.  Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials.

Authors:  Naomi Tanoue; Yasuhiro Matsuda; Hiroaki Yanagida; Hideo Matsumura; Takashi Sawase
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698