Literature DB >> 21383484

Accurate, reproducible measurement of acetone concentration in breath using selected ion flow tube-mass spectrometry.

Jack F Dummer1, Malina K Storer, Wan-Ping Hu, Maureen P Swanney, Gordon J Milne, Christopher M Frampton, Jenny M Scotter, G Kim Prisk, Michael J Epton.   

Abstract

Using selected ion flow tube-mass spectrometry (SIFT-MS) for on-line analysis, we aimed to define the optimal single-exhalation breathing manoeuvre from which a measure of expired acetone concentration could be obtained. Using known acetone concentrations in vitro, we determined the instrument's accuracy, inter-measurement variability and dynamic response time. Further, we determined the effects of expiratory flow and volume on acetone concentration in the breath of 12 volunteers and calculated intra-individual coefficients of variation (CVs). At acetone concentrations of 600-3000 ppb on 30 days over 2 months there was an instrument measurement bias of 8% that did not change over time, inter-day and intra-day CVs were 5.6% and 0.0%, respectively, and the 10-90% response time was 500 ± 50 ms (mean ± SE). Acetone concentrations at exhalation flows of 193 ± 18 (mean ± SD) and 313 ± 32 ml s(-1) were 619 ± 1.83 (geometric mean ± logSD) and 618 ± 1.82 ppb in the fraction 70-85% by volume of exhaled vital capacity (V(70-85%)) and 636 ± 1.82 (geometric mean ± logSD) and 631 ± 1.83 ppb in V(85-100%). A difference was observed between acetone concentrations in the V(70-85%) and V(85-100%) fractions (p < 0.01), but flow had no effect. Median intra-individual CVs were 1.6-2.6%. On-line SIFT-MS measurement of acetone concentration in a single exhalation requires control of exhaled volume but not flow, and yields low intra-individual CVs and is potentially useful in approximating blood glucose and monitoring metabolic stress.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21383484     DOI: 10.1088/1752-7155/4/4/046001

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  3 in total

Review 1.  Applications and Advances in Bioelectronic Noses for Odour Sensing.

Authors:  Tran Thi Dung; Yunkwang Oh; Seon-Jin Choi; Il-Doo Kim; Min-Kyu Oh; Moonil Kim
Journal:  Sensors (Basel)       Date:  2018-01-01       Impact factor: 3.576

2.  Effects of dietary nutrients on volatile breath metabolites.

Authors:  Olawunmi A Ajibola; David Smith; Patrik Spaněl; Gordon A A Ferns
Journal:  J Nutr Sci       Date:  2013-10-31

3.  A two-step synthesis of nanosheet-covered fibers based on α-Fe2O3/NiO composites towards enhanced acetone sensing.

Authors:  Mahmood Ul Haq; Zhen Wen; Ziyue Zhang; Shahid Khan; Zirui Lou; Zhizhen Ye; Liping Zhu
Journal:  Sci Rep       Date:  2018-01-26       Impact factor: 4.379

  3 in total