Literature DB >> 21382736

Validation of a passive stereophotogrammetry system for imaging of the breast: a geometric analysis.

T Catherwood1, E McCaughan, E Greer, R A J Spence, S A McIntosh, R J Winder.   

Abstract

The overall aim of this study was to assess the accuracy, reproducibility and stability of a high resolution passive stereophotogrammetry system to image a female mannequin torso, to validate measurements made on the textured virtual surface compared with those obtained using manual techniques and to develop an approach to make objective measurements of the female breast. 3D surface imaging was carried out on a textured female torso and measurements made in accordance with the system of mammometrics. Linear errors in measurements were less than 0.5mm, system calibration produced errors of less than 1.0mm over 94% over the surface and intra-rater reliability measured by ICC=0.999. The mean difference between manual and digital curved surface distances was 1.36 mm with maximum and minimum differences of 3.15 mm and 0.02 mm, respectively. The stereophotogrammetry system has been demonstrated to perform accurately and reliably with specific reference to breast assessment.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21382736     DOI: 10.1016/j.medengphy.2011.02.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

Review 1.  Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques.

Authors:  Michael P Chae; Warren Matthew Rozen; Robert T Spychal; David J Hunter-Smith
Journal:  Gland Surg       Date:  2016-04

2.  Stereophotogrammetric three-dimensional photography is an accurate and precise planimetric method for the clinical visualization and quantification of human papilloma virus-induced skin lesions.

Authors:  M Rijsbergen; L Pagan; T Niemeyer-van der Kolk; R Rijneveld; G Hogendoorn; C Lemoine; Y Meija Miranda; G Feiss; J N Bouwes Bavink; J Burggraaf; M I E van Poelgeest; R Rissmann
Journal:  J Eur Acad Dermatol Venereol       Date:  2019-03-12       Impact factor: 6.166

3.  New aspects in digital breast assessment: further refinement of a method for automated digital anthropometry.

Authors:  Robin Hartmann; Maximilian Weiherer; Daniel Schiltz; Magnus Baringer; Vivien Noisser; Vanessa Hösl; Andreas Eigenberger; Stephan Seitz; Christoph Palm; Lukas Prantl; Vanessa Brébant
Journal:  Arch Gynecol Obstet       Date:  2020-11-12       Impact factor: 2.344

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.