Literature DB >> 21382462

Comparison of in vitro and in vivo performance of a colonic delivery system.

Iman S Ahmed1, James W Ayres.   

Abstract

The aim of this work is to compare in vitro to in vivo performance of a colonic drug delivery system, made of small pectin-ethylcellulose coated drug beads. The delivery system was evaluated in vitro by conducting drug release studies in different dissolution media to mimic transit times and pH conditions in the stomach, small intestine and colon and in vivo by using gamma-scintigraphic studies in dogs and absorption studies in human volunteers under fed and fasted conditions. In vitro release studies indicated that drug release rate depended on the ratio of the pectin to ethylcellulose in the coat and the thickness of the coat. In vivo release studies obtained by deconvolution of biostudy data did not correlate with in vitro results obtained from most coat formulations. Beads showing ideal release profiles in vitro showed very poor performance in vivo and only those beads showing colonic premature drug release in vitro might be able to deliver the drug to the colon. Scintigraphic studies of a selected formulation showed that the labeled beads had an estimated gastric emptying time of 3 h, an estimated small intestine transit time of 2 h and an estimated colonic transit time of 36 h. Average in vivo lag times of the selected formulation from absorption studies in humans were found to be 6.1 h and 4.8 h under fed and fasted conditions, respectively. The C(max) was also observed at 6.8 h and 5.5 h on average, under fed and fasted conditions, respectively, which might indicate that release of drug from the beads, resulted from degradation of pectin in the coat by enzymatic action in the colon rather than by simple diffusion. Deconvolution of biostudy data showed that drug absorption continued on average for at least 12 h under both fed and fasted conditions.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21382462     DOI: 10.1016/j.ijpharm.2011.02.061

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  2 in total

1.  Characterization of soy polysaccharide and its in vitro and in vivo evaluation for application in colon drug delivery.

Authors:  B M Ursekar; P S Soni; Abhijit A Date; M S Nagarsenker
Journal:  AAPS PharmSciTech       Date:  2012-06-28       Impact factor: 3.246

2.  Development of cryptotanshinone-loaded pellets for angina chronotherapy: In vitro/in vivo prediction and evaluation.

Authors:  Zhenghua Li; Shuangshuang Zhang; Hongxiang Yan; Jianping Liu
Journal:  Asian J Pharm Sci       Date:  2018-03-12       Impact factor: 6.598

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.