An evaluation of electrical stimulation for improving periprosthetic attachment.

Brad M Isaacson1, Lucille B Brunker, Amalia A Brown, James P Beck, Gregory L Burns, Roy D Bloebaum.   

Abstract

Transcutaneous osseointegrated implants (TOI) have been shown to improve functionality for patients with limb loss by allowing direct skeletal attachment between an exoprosthesis and host bone. However, a lengthy rehabilitation period has limited the expansion of TOI and may be accelerated with electrical stimulation. The purpose of this study was to determine the ability of direct current (DC) cathode stimulation to enhance osseointegration of intramedullary implants in skeletally matured rabbits. Bilateral implants were inserted in the hind limbs of 25 adult female rabbits. The left hind limb of each animal was continually stimulated with a potential difference of 0.55 volts based on finite element analysis predictions. After sacrifice, the limbs were divided into two groups: Group I for histology and Group II for biomechanical testing. The bone-implant construct was evaluated in the Group I animals using appositional bone index (ABI), mineral apposition rates (MAR), histological staining, and scanning electron microscopy (SEM). Group II implants were sectioned and subjected to mechanical push-out tests. Data indicated no statistical differences for ABI, MAR, and porosity between the electrically stimulated implants (ESI) and the unstimulated control implants (UCI) at three weeks and six weeks. Higher mechanical push-out forces were observed in the UCI group at six weeks (p = 0.034). Data indicated that DC cathode stimulation may improve suboptimal implant "fit and fill" as an increase in trabecular bone was noted around the cathode in the ESI group. However, longer time duration animal studies and variations in electrical modalities may be required before electrically induced osseointegration becomes clinically feasible.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21381193     DOI: 10.1002/jbm.b.31803

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  6 in total

1.  Lattice cleaving: a multimaterial tetrahedral meshing algorithm with guarantees.

Authors:  Jonathan Bronson; Joshua A Levine; Ross Whitaker
Journal:  IEEE Trans Vis Comput Graph       Date:  2014-02       Impact factor: 4.579

2.  Establishing multiscale models for simulating whole limb estimates of electric fields for osseointegrated implants.

Authors:  Brad M Isaacson; Jeroen G Stinstra; Roy D Bloebaum; Paul F Pasquina; Rob S MacLeod
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-27       Impact factor: 4.538

3.  Enhancing osteoblast survival through pulsed electrical stimulation and implications for osseointegration.

Authors:  Emily Pettersen; Furqan A Shah; Max Ortiz-Catalan
Journal:  Sci Rep       Date:  2021-11-17       Impact factor: 4.379

Review 4.  Electrical stimulation to promote osseointegration of bone anchoring implants: a topical review.

Authors:  Emily Pettersen; Jenna Anderson; Max Ortiz-Catalan
Journal:  J Neuroeng Rehabil       Date:  2022-03-21       Impact factor: 4.262

5.  DC electrical stimulation enhances proliferation and differentiation on N2a and MC3T3 cell lines.

Authors:  Daniel Martín; J Bocio-Nuñez; Santiago F Scagliusi; Pablo Pérez; Gloria Huertas; Alberto Yúfera; Mercè Giner; Paula Daza
Journal:  J Biol Eng       Date:  2022-10-13       Impact factor: 6.248

6.  Protecting the skin-implant interface with transcutaneous silver-coated skin-and-bone-integrated pylon in pig and rabbit dorsum models.

Authors:  Maxim Shevtsov; Dmitriy Gavrilov; Natalia Yudintceva; Elena Zemtsova; Andrei Arbenin; Vladimir Smirnov; Irina Voronkina; Polina Adamova; Miralda Blinova; Nataliya Mikhailova; Oleg Galibin; Michael Akkaoui; Mark Pitkin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-09-16       Impact factor: 3.405

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.