Literature DB >> 21381105

Visualization and quantification of intestinal transit and motor function by real-time tracking of 19F labeled capsules in humans.

Tobias Hahn1, Sebastian Kozerke, Werner Schwizer, Michael Fried, Peter Boesiger, Andreas Steingoetter.   

Abstract

A combined (19)F and (1)H MRI framework for the assessment of human intestinal transit and motor function is presented. This framework consists of silicone coated polychlorotrifluoroethylene capsules filled with perfluoro-[15]-crown-5-ether as (19)F marker, a flexible (19)F surface coil and a (19)F projection imaging sequence, allowing for real-time tracking of a single or multiple capsules. The capsules (length 11.5 mm, Ø 7.2 mm) contain 140 μL perfluoro-[15]-crown-5-ether and were tested for cytotoxicity and leakage prior to oral administration. A balanced SSFP projection sequence was implemented, yielding a temporal resolution of 133 ms. Optional multi-frequency excitation, allowing for interleaved tracking of differently labeled (19)F capsules, was incorporated. The passage of the (19)F capsules through intestinal sections was monitored in two healthy volunteers. Capsule coordinates were successfully coregistered with anatomical reference scans. Intestinal motility, residence times, lengths and forward velocities were determined. Simultaneous tracking of two capsules allowed for the assessment of peristaltic patterns with correction for respiratory motion. By providing the means for real-time multiple capsule tracking and high resolution anatomical imaging, the presented multinuclear imaging framework has the potential to provide important supplemental information for physiological and pharmaceutical research.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21381105     DOI: 10.1002/mrm.22822

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Gastric transit and small intestinal transit time and motility assessed by a magnet tracking system.

Authors:  Jonas Worsøe; Lotte Fynne; Tine Gregersen; Vincent Schlageter; Lisbet A Christensen; Jens F Dahlerup; Nico J M Rijkhoff; Søren Laurberg; Klaus Krogh
Journal:  BMC Gastroenterol       Date:  2011-12-29       Impact factor: 3.067

Review 2.  Imaging Measurement of Whole Gut Transit Time in Paediatric and Adult Functional Gastrointestinal Disorders: A Systematic Review and Narrative Synthesis.

Authors:  Hayfa Sharif; David Devadason; Nichola Abrehart; Rebecca Stevenson; Luca Marciani
Journal:  Diagnostics (Basel)       Date:  2019-12-13

3.  Application of In Vivo MRI Imaging to Track a Coated Capsule and Its Disintegration in the Gastrointestinal Tract in Human Volunteers.

Authors:  Sarah Sulaiman; Pavel Gershkovich; Caroline L Hoad; Matthew Calladine; Robin C Spiller; Snow Stolnik; Luca Marciani
Journal:  Pharmaceutics       Date:  2022-01-24       Impact factor: 6.321

4.  Novel MRI tests of orocecal transit time and whole gut transit time: studies in normal subjects.

Authors:  G Chaddock; C Lam; C L Hoad; C Costigan; E F Cox; E Placidi; I Thexton; J Wright; P E Blackshaw; A C Perkins; L Marciani; P A Gowland; R C Spiller
Journal:  Neurogastroenterol Motil       Date:  2013-10-25       Impact factor: 3.598

Review 5.  Magnetic resonance imaging biomarkers of gastrointestinal motor function and fluid distribution.

Authors:  Asseel Khalaf; Caroline L Hoad; Robin C Spiller; Penny A Gowland; Gordon W Moran; Luca Marciani
Journal:  World J Gastrointest Pathophysiol       Date:  2015-11-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.