Literature DB >> 2138090

Effects of the Schirmer test on the fibrinolytic system in the tear fluid.

G B van Setten1, R Stephens, T Tervo, E M Salonen, A Tarkkanen, A Vaheri.   

Abstract

Human tear fluid was collected with blunted glass capillaries before and after performing the Schirmer test (ST). The test caused an increase in the tear fluid (TF) plasmin concentration (from 0.40 +/- 0.29 microgram ml-1 (mean +/- S.E.M.) to 1.14 +/- 0.26 microgram ml-1; Mann-Whitney test P less than 0.001) and a decrease in plasminogen activator activity (from 2.04 +/- 0.24 IU ml-1 to 1.04 +/- 0.17 IU ml-1; Mann-Whitney test P less than 0.002). In the filter paper used for ST, that segment that had been in contact with the conjunctiva (5 mm) usually contained higher amounts of plasmin than the following 5 mm of the paper overhanging the lidmargin. The present results indicate that the TF collection may affect the plasminogen activator-plasmin system in TF, depending on the collection method used.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2138090     DOI: 10.1016/0014-4835(90)90223-h

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  6 in total

1.  Ocular hypotensive effect of topical ketanserin in timolol users.

Authors:  L Mastropasqua; M Ciancaglini; P Carpineto; C Costagliola
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-03       Impact factor: 3.117

2.  Effect of topical ketanserin administration on intraocular pressure.

Authors:  C Costagliola; G Iuliano; M Rinaldi; V Russo; G Scibelli; L Mastropasqua
Journal:  Br J Ophthalmol       Date:  1993-06       Impact factor: 4.638

3.  Diagnostic biomarkers in tear fluid: from sampling to preanalytical processing.

Authors:  Franziska Bachhuber; André Huss; Makbule Senel; Hayrettin Tumani
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

4.  Comparison of Capillary and Schirmer Strip Tear Fluid Sampling Methods Using SWATH-MS Proteomics Approach.

Authors:  Janika Nättinen; Ulla Aapola; Antti Jylhä; Anu Vaajanen; Hannu Uusitalo
Journal:  Transl Vis Sci Technol       Date:  2020-02-13       Impact factor: 3.283

5.  Noninvasive Self-diagnostic Device for Tear Collection and Glucose Measurement.

Authors:  Seung Ho Lee; Yong Chan Cho; Young Bin Choy
Journal:  Sci Rep       Date:  2019-03-18       Impact factor: 4.379

6.  An Extensive Study of Phenol Red Thread as a Novel Non-Invasive Tear Sampling Technique for Proteomics Studies: Comparison with Two Commonly Used Methods.

Authors:  Gábor Kecskeméti; Edit Tóth-Molnár; Tamás Janáky; Zoltán Szabó
Journal:  Int J Mol Sci       Date:  2022-08-03       Impact factor: 6.208

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.