INTRODUCTION: We assessed the utility of EBC pH as a biomarker in COPD in a large cohort of well-characterised individuals with COPD and control subjects from the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE) study. We also determined short term reproducibility and the response of EBC to oral prednisolone. METHODS: EBC was collected with R-Tubes(TM), using techniques for sampling and measurement that have been shown to be reproducible. RESULTS: EBC pH was lower in COPD (n = 676, 7.29 ± SD 0.60) and in smoking controls (n = 31, 7.18 ± 0.85), compared with non-smoking controls (n = 50, 7.59 ± 0.44, p = 0.0008 and 0.0033 respectively), but was not different between COPD and smoking controls. There was no relationship between EBC pH and disease severity, as assessed by the percent predicted FEV(1), nor with airway inflammation as assessed by sputum leukocyte counts. Treatment with 20 mg.day-1 prednisolone for 4 weeks did not change EBC pH. CONCLUSION: EBC pH is lower in COPD than in healthy control non-smokers, but does not differentiate COPD from smokers without COPD, relate to disease severity or to airway inflammation, and does not respond to corticosteroids. EBC pH therefore does not appear to be a useful biomarker in COPD.
INTRODUCTION: We assessed the utility of EBC pH as a biomarker in COPD in a large cohort of well-characterised individuals with COPD and control subjects from the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE) study. We also determined short term reproducibility and the response of EBC to oral prednisolone. METHODS:EBC was collected with R-Tubes(TM), using techniques for sampling and measurement that have been shown to be reproducible. RESULTS:EBC pH was lower in COPD (n = 676, 7.29 ± SD 0.60) and in smoking controls (n = 31, 7.18 ± 0.85), compared with non-smoking controls (n = 50, 7.59 ± 0.44, p = 0.0008 and 0.0033 respectively), but was not different between COPD and smoking controls. There was no relationship between EBC pH and disease severity, as assessed by the percent predicted FEV(1), nor with airway inflammation as assessed by sputum leukocyte counts. Treatment with 20 mg.day-1 prednisolone for 4 weeks did not change EBC pH. CONCLUSION:EBC pH is lower in COPD than in healthy control non-smokers, but does not differentiate COPD from smokers without COPD, relate to disease severity or to airway inflammation, and does not respond to corticosteroids. EBC pH therefore does not appear to be a useful biomarker in COPD.
Authors: Anita Ljubičić Ćalušić; Veda Marija Varnai; Anka Ozana Cavlović; Maja Segvić Klarić; Ružica Beljo; Ljerka Prester; Jelena Macan Journal: Int Arch Occup Environ Health Date: 2012-09-25 Impact factor: 3.015
Authors: D B Day; J Xiang; J Mo; M A Clyde; C J Weschler; F Li; J Gong; M Chung; Y Zhang; J Zhang Journal: Indoor Air Date: 2018-01-24 Impact factor: 5.770
Authors: Syed H Haider; Arul Veerappan; George Crowley; Erin J Caraher; Dean Ostrofsky; Mena Mikhail; Rachel Lam; Yuyan Wang; Maria Sunseri; Sophia Kwon; David J Prezant; Mengling Liu; Ann Marie Schmidt; Anna Nolan Journal: Am J Respir Cell Mol Biol Date: 2020-08 Impact factor: 6.914
Authors: Michael Schivo; Timothy E Albertson; Angela Haczku; Nicholas J Kenyon; Amir A Zeki; Brooks T Kuhn; Samuel Louie; Mark V Avdalovic Journal: J Investig Med Date: 2017-03-03 Impact factor: 2.895
Authors: Janet G Shaw; Annalicia Vaughan; Annette G Dent; Phoebe E O'Hare; Felicia Goh; Rayleen V Bowman; Kwun M Fong; Ian A Yang Journal: J Thorac Dis Date: 2014-11 Impact factor: 2.895