Literature DB >> 21376494

Image fusion in dual energy computed tomography for detection of various anatomic structures--effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality.

Jijo Paul1, Ralf W Bauer, Werner Maentele, Thomas J Vogl.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality.
MATERIAL AND METHODS: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mAs; collimation-2×32×0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test.
RESULTS: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P≤0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2±12.8 Hounsfield Units (HU), 204.8±14.4 HU, 267.5±18.6 HU, 311.9±22.3 HU, 347.3±24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P=0.012 and P=0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0.6.
CONCLUSION: Different fusion factors used to create images in DECT cause statistically significant differences in CT value, SNR, CNR and image quality. Best results obtained using the weighting factor 0.6 for all anatomic structures used in this study.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21376494     DOI: 10.1016/j.ejrad.2011.02.023

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

Review 1.  Dual-energy computed tomography applications in uroradiology.

Authors:  Jong Park; Hersh Chandarana; Michael Macari; Alec J Megibow
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

2.  Image-guided microwave thermoablation of hepatic tumours using novel robotic guidance: an early experience.

Authors:  Emmanuel C Mbalisike; Thomas J Vogl; Stefan Zangos; Katrin Eichler; Prakash Balakrishnan; Jijo Paul
Journal:  Eur Radiol       Date:  2014-08-23       Impact factor: 5.315

3.  Comparing image quality of single- and dual-energy computed tomography of the brain.

Authors:  Doris Dodig; Slavica Kovačić; Zrinka Matana Kaštelan; Iva Žuža; Filip Benić; Jurković Slaven; Damir Miletić; Zoran Rumboldt
Journal:  Neuroradiol J       Date:  2020-04-21

4.  Non-linear blending of dual-energy CT data improves depiction of late iodine enhancement in chronic myocardial infarction.

Authors:  Julian L Wichmann; Xiaohan Hu; J Matthias Kerl; Boris Schulz; Boris Bodelle; Claudia Frellesen; Thomas Lehnert; Thomas J Vogl; Ralf W Bauer
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-09       Impact factor: 2.357

Review 5.  Dual-Energy CT: What the Neuroradiologist Should Know.

Authors:  Alida A Postma; Marco Das; Annika A R Stadler; Joachim E Wildberger
Journal:  Curr Radiol Rep       Date:  2015

6.  Therapeutic experience of 289 elderly patients with biliary diseases.

Authors:  Zong-Ming Zhang; Zhuo Liu; Li-Min Liu; Chong Zhang; Hong-Wei Yu; Bai-Jiang Wan; Hai Deng; Ming-Wen Zhu; Zi-Xu Liu; Wen-Ping Wei; Meng-Meng Song; Yue Zhao
Journal:  World J Gastroenterol       Date:  2017-04-07       Impact factor: 5.742

7.  Quality Assessment of Tc-99m Methylene Diphosphonate (MDP) Radiopharmaceutical Prepared Using Different Cold Kit Fractionation Methods.

Authors:  Arun Kumar Thokchom; Rajesh Kumar; Sanjay Bharati
Journal:  Indian J Nucl Med       Date:  2022-03-25

Review 8.  Dual-energy CT imaging of thoracic malignancies.

Authors:  Long Jiang Zhang; Gui Fen Yang; Sheng Yong Wu; Jian Xu; Guang Ming Lu; U Joseph Schoepf
Journal:  Cancer Imaging       Date:  2013-03-06       Impact factor: 3.909

Review 9.  Multiparametric Evaluation of Head and Neck Squamous Cell Carcinoma Using a Single-Source Dual-Energy CT with Fast kVp Switching: State of the Art.

Authors:  Stephanie Lam; Rajiv Gupta; Hillary Kelly; Hugh D Curtin; Reza Forghani
Journal:  Cancers (Basel)       Date:  2015-11-06       Impact factor: 6.639

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.