Literature DB >> 21374651

Determination of free and total warfarin concentrations in plasma using UPLC MS/MS and its application to a patient samples.

Mahasen A Radwan1, Ghada A Bawazeer, Nouf M Aloudah, Bushra T AlQuadeib, Hassan Y Aboul-Enein.   

Abstract

Warfarin is routinely monitored by assessing its pharmacologic effects on the international normalized ratio. However, having a patient with INR not responding to increasing warfarin dose mandates a direct measurement of warfarin concentrations (total and free) for better patient clinical management of warfarin therapy. Therefore, a new fully validated specific, precise and accurate ultra-performance liquid chromatography tandem mass spectrometry was developed for the determination of free and total warfarin in human plasma. Free warfarin was measured in plasma filtrate, prepared by ultrafiltration, and sample pretreatment involved protein precipitation with acetonitrile. Linear response (r(2) ≥0.99) was observed over the studied range of free and total warfarin, with the lower limit of detection of 0.25 ng/mL. The intra- and inter-day precision (relative standard deviation) values were <10% and the accuracy (relative error) was ≤6.6 for free and total warfarin. There was no significant difference (p>0.05) between inter- and intra-day studies for the free and total warfarin, which confirmed the reproducibility of the assay method. The mean extraction efficiency was 88.6-107.2% of free and total warfarin. The assay was sensitive to follow warfarin pharmacokinetics (free and total) in a patient with resistance to warfarin up to 24 h after a daily dose of warfarin.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21374651     DOI: 10.1002/bmc.1616

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  5 in total

1.  Fluorescence Determination of Warfarin Using TGA-capped CdTe Quantum Dots in Human Plasma Samples.

Authors:  A Dehbozorgi; J Tashkhourian; S Zare
Journal:  J Fluoresc       Date:  2015-10-19       Impact factor: 2.217

2.  Monitoring the distribution of warfarin in blood plasma.

Authors:  Annika M Rosengren; Björn C G Karlsson; Ian A Nicholls
Journal:  ACS Med Chem Lett       Date:  2012-06-20       Impact factor: 4.345

3.  Development of a chiral micellar electrokinetic chromatography-tandem mass spectrometry assay for simultaneous analysis of warfarin and hydroxywarfarin metabolites: application to the analysis of patients serum samples.

Authors:  Xiaochun Wang; Jingguo Hou; Michael Jann; Yuen Yi Hon; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2012-11-26       Impact factor: 4.759

4.  Warfarin modulates the nitrite reductase activity of ferrous human serum heme-albumin.

Authors:  Paolo Ascenzi; Grazia R Tundo; Gabriella Fanali; Massimo Coletta; Mauro Fasano
Journal:  J Biol Inorg Chem       Date:  2013-09-15       Impact factor: 3.358

5.  Quantification of Warfarin in Dried Rat Plasma Spots by High-Performance Liquid Chromatography with Tandem Mass Spectrometry.

Authors:  Alexander Chernonosov
Journal:  J Pharm (Cairo)       Date:  2016-12-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.