Comparative evaluation of GFAAS and ICP-MS for analyses of cadmium in blood.

Yoshinari Fukui1, Fumiko Ohashi, Sonoko Sakuragi, Jiro Moriguchi, Masayuki Ikeda.   

Abstract

Cadmium in blood (Cd-B) is an important indicator, next to Cd in urine, in biological monitoring of exposure to Cd. The present study was initiated to examine compatibility in results of analysis for Cd-B between graphite furnace atomic absorption spectrophotometry (GFAAS) and inductively-coupled plasma mass-spectrometry (ICP-MS). For this purpose, 1,159 blood samples were collected from adult women (with no occupational exposure to Cd) in eight prefectures nation-widely in Japan. The samples were analyzed by the two methods; geometric mean (the maximum) concentrations were 1.22 (6.90) μg/l by ICP-MS, and 1.47 (7.40) μg/l by GFAAS. Statistical analyses showed that there was a close correlation between the results by the two methods. The regression line (with ICP-MS and GFAAS results as an independent variable and a dependent variable, respectively) had a slope close to one and an intercept next to zero to suggest that ICP-MS gave values compatible with that of GFAAS. Further analysis with the ratio of Cd-B by GFAAS over that by ICP-MS revealed that the two results were close to each other, and that the agreement was even closer when Cd-B was >2 μg/l. Thus, the two methods can be employed inter-convertibly when Cd-B is relatively high, e.g. >2 μg/l. Care may need to be practiced, however, for possible 'between methods' difference when Cd-B is low, e.g., ≤2 μg/l.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21372439     DOI: 10.2486/indhealth.ms1194

Source DB:  PubMed          Journal:  Ind Health        ISSN: 0019-8366            Impact factor:   2.179


  3 in total

1.  Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters.

Authors:  Malgorzata Trzcinka-Ochocka; Renata Brodzka; Beata Janasik
Journal:  J Clin Lab Anal       Date:  2014-11-25       Impact factor: 2.352

2.  Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry.

Authors:  Man Xiao; Zaiju Huang; Jing Cai; Jinghui Jia; Yuzeng Zhang; Weihong Dong; Zehua Wang
Journal:  PeerJ       Date:  2017-01-18       Impact factor: 2.984

3.  The assessment of the usability of selected instrumental techniques for the elemental analysis of biomedical samples.

Authors:  Karolina Planeta; Aldona Kubala-Kukus; Agnieszka Drozdz; Katarzyna Matusiak; Zuzanna Setkowicz; Joanna Chwiej
Journal:  Sci Rep       Date:  2021-02-12       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.