Troy D Jaskowski1, Andrew Wilson, Harry R Hill, Anne E Tebo. 1. Associated Regional and University Pathologists (ARUP) Institute for Clinical and Experimental Pathology, University of Utah School of Medicine, Salt Lake City, UT 84108-1221, United States.
Abstract
BACKGROUND: The aim of this study was to compare the correlation between new diagnostic methodologies for detecting anti-polymyositis/scleroderma (anti-PM/Scl) IgG antibodies associated with myositis and/or systemic scleroderma assays with existing platforms. METHODS: Sera from 164 samples previously tested for anti-PM/Scl IgG antibody by immunodiffusion, ID; 171 sera screened for anti-PM/Scl IgG by immunoprecipitation, IP; an additional group of 215 sera tested by ID and 46 healthy blood donor sera were retrospectively evaluated. Anti-PM/Scl IgG antibodies were measured using three PM/Scl-100 specific enzyme immunoassays (EIAs), PM1-alpha (PM1-α) EIA and a line immunoblot assay (LIA) for anti-PM/Scl-75 and -100 IgG antibodies. Selected samples were tested for the presence of antinuclear antibody (ANA) by indirect fluorescent antibody (IFA) assay. RESULTS: The overall agreement between ID and all anti-PM/Scl IgG EIAs as determined by Crohnbach's alpha was unacceptable (α<0.50). The concordance between the IP and either LIA or PM1-α EIA was greater than 90% however, the best agreement was seen between the IP and LIA PM/Scl-100 assays (98.3%). Compared to the LIA PM/Scl-75 and PM1-α tests, the LIA PM/Scl-100 IgG assay showed the best specificity in the healthy control group. CONCLUSIONS: Our results demonstrate considerable differences between assays for detecting anti-PM/Scl IgG antibodies which cannot be attributable to heterogeneity in antibody response alone. Further characterization and standardization of these assays are needed.
BACKGROUND: The aim of this study was to compare the correlation between new diagnostic methodologies for detecting anti-polymyositis/scleroderma (anti-PM/Scl) IgG antibodies associated with myositis and/or systemic scleroderma assays with existing platforms. METHODS: Sera from 164 samples previously tested for anti-PM/Scl IgG antibody by immunodiffusion, ID; 171 sera screened for anti-PM/Scl IgG by immunoprecipitation, IP; an additional group of 215 sera tested by ID and 46 healthy blood donor sera were retrospectively evaluated. Anti-PM/Scl IgG antibodies were measured using three PM/Scl-100 specific enzyme immunoassays (EIAs), PM1-alpha (PM1-α) EIA and a line immunoblot assay (LIA) for anti-PM/Scl-75 and -100 IgG antibodies. Selected samples were tested for the presence of antinuclear antibody (ANA) by indirect fluorescent antibody (IFA) assay. RESULTS: The overall agreement between ID and all anti-PM/Scl IgG EIAs as determined by Crohnbach's alpha was unacceptable (α<0.50). The concordance between the IP and either LIA or PM1-α EIA was greater than 90% however, the best agreement was seen between the IP and LIA PM/Scl-100 assays (98.3%). Compared to the LIA PM/Scl-75 and PM1-α tests, the LIA PM/Scl-100 IgG assay showed the best specificity in the healthy control group. CONCLUSIONS: Our results demonstrate considerable differences between assays for detecting anti-PM/Scl IgG antibodies which cannot be attributable to heterogeneity in antibody response alone. Further characterization and standardization of these assays are needed.