Literature DB >> 21368603

A comparative study of F-18 FDG PET and 201Tl scintigraphy for detection of primary malignant bone and soft-tissue tumors.

Yuka Yamamoto1, Yoji Kawaguchi, Yoshiro Kawase, Yukito Maeda, Yoshihiro Nishiyama.   

Abstract

PURPOSE: The purpose of this study was to compare 2-[F-18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and Tl-201 chloride (Tl) scintigraphy for detection of primary malignant bone and soft-tissue tumors.
MATERIALS AND METHODS: A total of 40 patients with suspicion of malignant bone and soft-tissue tumors were examined. FDG PET imaging was performed at 1-hour post-FDG injection. Tl planar and single photon emission computed tomography images were acquired 10 minutes (early) and 2 hours (delayed) after injection of Tl. We evaluated FDG and Tl uptake visually and semiquantitatively using standardized uptake value and tumor to contralateral normal tissue ratio on planar images, respectively.
RESULTS: Of the 33 patients with malignant tumors, all but 2 liposarcomas showed positive accumulation on FDG PET. However, all 7 benign lesions were also positive on FDG PET. Both early and delayed Tl images were positive for 27 of the 33 malignant tumors. Of the 6 false-negative cases on Tl images, 5 were liposarcomas. Both early and delayed Tl images were negative for 5 of the 7 benign lesions. The sensitivity of FDG PET for detection of primary malignant bone and soft-tissue tumors was 94% and the specificity, 0%. The corresponding values for Tl scintigraphy were 82% and 71%. The mean FDG standardized uptake value in malignant tumors was higher than that in benign lesions, but this difference was not statistically significant. Statistically significant differences were observed between malignant and benign lesions for both early and delayed tumor to contralateral normal tissue ratios.
CONCLUSIONS: FDG PET was found to be more sensitive than Tl scintigraphy for primary malignant bone and soft-tissue tumors, although it was less specific.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21368603     DOI: 10.1097/RLU.0b013e31820ade17

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  3 in total

1.  Use of MR arthrography in detecting tears of the ligamentum teres with arthroscopic correlation.

Authors:  Connie Y Chang; Corey M Gill; Ambrose J Huang; Frank J Simeone; Martin Torriani; Joseph C McCarthy; Miriam A Bredella
Journal:  Skeletal Radiol       Date:  2014-12-20       Impact factor: 2.199

2.  The value of intratumoral heterogeneity of (18)F-FDG uptake to differentiate between primary benign and malignant musculoskeletal tumours on PET/CT.

Authors:  Masatoyo Nakajo; Masayuki Nakajo; Megumi Jinguji; Yoshihiko Fukukura; Yoshiaki Nakabeppu; Atsushi Tani; Takashi Yoshiura
Journal:  Br J Radiol       Date:  2015-09-04       Impact factor: 3.039

3.  Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma: A Systematic Review and Meta-Analysis.

Authors:  Fanxiao Liu; Qingyu Zhang; Dezhi Zhu; Fengxia Liu; Zhenfeng Li; Jianmin Li; Bomin Wang; Dongsheng Zhou; Jinlei Dong
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

  3 in total