Literature DB >> 21367602

Phosphorus retention in a constructed wetland system used to treat dairy wastewater.

A O'Neill1, R H Foy, D H Phillips.   

Abstract

The aim of this study was to develop an input/output mass balance to predict phosphorus retention in a five pond constructed wetland system (CWS) at Greenmount Farm, County Antrim, Northern Ireland. The mass balance was created using 14-months of flow data collected at inflow and outflow points on a weekly basis. Balance outputs were correlated with meteorological parameters, such as daily air temperature and hydrological flow, recorded daily onsite. The mass balance showed that phosphorus retention within the system exceeded phosphorus release, illustrating the success of this CWS to remove nutrients from agricultural effluent from a dairy farm. The last pond, pond 5, showed the greatest relative retention of 86%. Comparison of retention and mean air temperature highlighted a striking difference in trends between up-gradient and down-gradient ponds, with up-gradient ponds 1 and 2 displaying a positive quadratic relationship and down-gradient ponds 3 through 5 displaying a negative quadratic relationship.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21367602     DOI: 10.1016/j.biortech.2011.01.075

Source DB:  PubMed          Journal:  Bioresour Technol        ISSN: 0960-8524            Impact factor:   9.642


  4 in total

Review 1.  A comprehensive review on utilization of wastewater from coffee processing.

Authors:  Supriya Rattan; A K Parande; V D Nagaraju; Girish K Ghiwari
Journal:  Environ Sci Pollut Res Int       Date:  2015-01-20       Impact factor: 4.223

2.  Bioaugmentation in a pilot-scale constructed wetland to treat domestic wastewater in summer and autumn.

Authors:  Haiyan Pei; Yuanyuan Shao; Christopher Peter Chanway; Wenrong Hu; Panpan Meng; Zheng Li; Yang Chen; Guangxiang Ma
Journal:  Environ Sci Pollut Res Int       Date:  2016-01-12       Impact factor: 4.223

3.  The use of a hybrid Sequential Biofiltration System for the improvement of nutrient removal and PCB control in municipal wastewater.

Authors:  Edyta Kiedrzyńska; Magdalena Urbaniak; Marcin Kiedrzyński; Adam Jóźwik; Agnieszka Bednarek; Ilona Gągała; Maciej Zalewski
Journal:  Sci Rep       Date:  2017-07-14       Impact factor: 4.379

4.  Spatial Variation of Phosphorous Retention Capacity in Subsurface Flow Constructed Wetlands: Effect of Wetland Type and Inflow Loading.

Authors:  Guangwei Yu; Meijuan Tan; Yunxiao Chong; Xinxian Long
Journal:  PLoS One       Date:  2015-07-28       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.