Literature DB >> 21365341

Evaluation of a trainer phantom in the learning phase of sentinel lymph node identification in breast cancer.

Pierre Lèguevaque1, Stephanie Motton, Frédéric Courbon, Marcel Ricard, Isabelle Berry, Denis Querleu.   

Abstract

BACKGROUND: The concept of a learning phase is difficult to implement in a university setting, as it is unacceptable to subject a patient who requires only lymphadenectomy to axillary dissection for the purpose of training surgeons. We therefore sought to evaluate intraoperative sentinel node detection using a phantom, the Senti-Trainer. Learning phases on the Senti-Trainer and detection rate were assessed in order to determine whether the proficiency of surgeons in training improved with the number of procedures.
METHODS: Twenty residents each performed 30 detection procedures of a sentinel node on the silicon phantom. Each resident was evaluated at each procedure, and an observation report was made every five procedures. Evaluation was single-blind as the surgeons did not know the result of the previous detection and were aware of the results only after the thirtieth procedure.
RESULTS: The mean detection rate was 75% during the first procedure and reached 95% (or 5% detection errors) at the 30th procedure (p<0.0001; OR=6.33 with a 95% CI=[2.31; 17.33]). Proficiency in sentinel lymph node (SLN) identification also increased with the number of procedures performed. The ability to localize SLN improved during the learning phase with the increasing number of procedures performed. Mean detection time during the 30 procedures was 150 s (range: 115-210 s).
CONCLUSIONS: Training on a phantom showed that this is a valuable teaching tool that enables surgeons to become familiar with gamma probes. It cannot replace the clinical training phase, but is an important aid to proficiency in intraoperative detection.

Entities:  

Mesh:

Year:  2011        PMID: 21365341     DOI: 10.1007/s00268-011-0997-7

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  19 in total

1.  The illusion of the learning phase for lymphatic mapping.

Authors:  P J Tanis; O E Nieweg; A A M Hart; B B R Kroon
Journal:  Ann Surg Oncol       Date:  2002-03       Impact factor: 5.344

Review 2.  Is lymphatic mapping in breast cancer adequate and safe?

Authors:  O E Nieweg; E J Rutgers; L Jansen; R A Valdés Olmos; J L Peterse; K A Hoefnagel; B B Kroon
Journal:  World J Surg       Date:  2001-05-14       Impact factor: 3.352

Review 3.  How many cases are enough for accreditation in sentinel lymph node biopsy in breast cancer?

Authors:  Elias E Sanidas; Eelco de Bree; Dimitris D Tsiftsis
Journal:  Am J Surg       Date:  2003-03       Impact factor: 2.565

4.  A model for teaching sentinel lymph node mapping and excision and axillary lymph node dissection.

Authors:  Gary L Dunnington
Journal:  J Am Coll Surg       Date:  2003-07       Impact factor: 6.113

5.  A computerized gamma probe simulator to train surgeons in the localization of sentinel nodes.

Authors:  Alan Britten; Valentine R Newey; Ron Clarke
Journal:  Nucl Med Commun       Date:  2007-03       Impact factor: 1.690

6.  Effects of sentinel lymph node biopsy on surgical residency training.

Authors:  Susanna Shin; Keith Fournier; Frederick Cole; Christine Laronga
Journal:  Am Surg       Date:  2006-09       Impact factor: 0.688

7.  Prevalence of teaching sentinel lymph node biopsy for breast cancer in general surgery residency programs.

Authors:  Kurt G Davis; John P Schriver
Journal:  Curr Surg       Date:  2002 Jul-Aug

Review 8.  Radioguided sentinel lymph node biopsy in breast cancer surgery.

Authors:  G Mariani; L Moresco; G Viale; G Villa; M Bagnasco; G Canavese; J Buscombe; H W Strauss; G Paganelli
Journal:  J Nucl Med       Date:  2001-08       Impact factor: 10.057

Review 9.  The learning curve for sentinel node biopsy in breast cancer: practical considerations.

Authors:  R K Orr; J L Hoehn; N F Col
Journal:  Arch Surg       Date:  1999-07

Review 10.  A training simulator for sentinel node biopsy in breast cancer: a new standard.

Authors:  M R S Keshtgar; D W Chicken; W A Waddington; W Raven; P J Ell
Journal:  Eur J Surg Oncol       Date:  2005-03       Impact factor: 4.424

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.