Literature DB >> 21365132

Effect of a metal primer on the bond strength of the resin-metal interface.

Anderson Pinheiro de Freitas1, Paulo Afonso Silveira Francisconi.   

Abstract

To evaluate the effect of different surface treatments on shear bond strength between a metallic alloy (Co-Cr-Mo - Remanium CD) and a resin cement (Rely X TM) and to evaluate the mode of fracture after testing, forty couples of metallic-alloy disks were melted, regularized, polished, submitted to four thermal cycles (Vacuum, 960ºC, 8 minutes) and randomly separated into four groups. Each group received a different type of treatment: Group PSP: Polished with sandpaper 600; Group PCP: Polished with sandpaper 600 and application of the metal primer Alloy Primer (Kuraray); Group JSP: Sandblasted with 100µm aluminum oxide; Group JCP: Sandblasted with 100mm aluminum oxide and treated with a metal Primer. The groups were cemented and stored in distilled water at 37ºC for 36 hours and submitted to the shear bond strength test. The mean and standard deviation (in Kgf/cm²) obtained for each group was: PSP 4.0/0.4; PCP 88.9/33.6; JSP 163.2/27.6; JCP 144.5/54.0. After the statistical analysis the authors concluded that: the highest values were obtained for the sandblasted groups (JSP, JCP), regardless of the primer application; the Alloy Primer increased the retention between the Rely X cement and the polished surface of the Co-Cr-Mo alloy, yet its bond strength was not greater than that obtained with sandblasting; all specimens showed adhesive failures in the tested interface.

Entities:  

Year:  2004        PMID: 21365132     DOI: 10.1590/s1678-77572004000200006

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  4 in total

1.  Effects of Er:YAG laser treatments on surface roughness of base metal alloys.

Authors:  Göknil Ergün Kunt; Ahmet Umut Güler; Gözlem Ceylan; Ibrahim Duran; Pelin Ozkan; Tuğrul Kirtiloğlu
Journal:  Lasers Med Sci       Date:  2010-10-20       Impact factor: 3.161

2.  Comparison of Bond Strength in the Different Class of Resin Cements to Cast and CAD/CAM Co-Cr Alloys.

Authors:  Leyla Sadighpour; Azam S Mostafavi; Maryam Pirmoradian; Fatemeh Alipuryalda
Journal:  Int J Dent       Date:  2021-12-26

3.  Influence of different surface treatments of nickel chrome metal alloy and types of metal primer monomers on the tensile bond strength of a resin cement.

Authors:  Raghad S Jamel; Màan M Nayif; Mohammed A Abdulla
Journal:  Saudi Dent J       Date:  2019-03-18

4.  The Effect of Artificial Aging on The Bond Strength of Heat-activated Acrylic Resin to Surface-treated Nickel-chromium-beryllium Alloy.

Authors:  Youssef S Al Jabbari; Spiros Zinelis; Sara M Al Taweel; William W Nagy
Journal:  Open Dent J       Date:  2016-04-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.