Use of ultrasound to facilitate femoral nerve block with stimulating catheter.

Min Li1, Ting Xu, Wen-yong Han, Xue-dong Wang, Dong-lin Jia, Xiang-yang Guo.   

Abstract

BACKGROUND: The adjunction of ultrasound to nerve stimulation has been proven to improve single-injection peripheral nerve block quality. However, few reports have been published determining whether ultrasound can facilitate continuous nerve blocks. In this study, we tested the hypothesis that the addition of ultrasound to nerve stimulation facilitates femoral nerve blocks with a stimulating catheter.
METHODS: In this prospective randomized study, patients receiving continuous femoral nerve blocks for total knee replacement were randomly assigned to either the ultrasound guidance combined with stimulating catheter group (USNS group; n = 60) or the stimulating catheter alone group (NS group; n = 60). The primary end point was the procedure time (defined as the time from first needle contact with the skin until correct catheter placement). The numbers of needle passes and catheter insertions, onset and quality of femoral nerve blocks, postoperative pain score, and early knee function were also recorded.
RESULTS: The procedure time was significantly less in the USNS group than in the NS group (9.0 (6.0 - 22.8) minutes vs. 13.5 (6.0 - 35.9) minutes, P = 0.024). The numbers of needle passes and catheter insertions were also significantly less in the USNS group. A greater complete block rate was achieved at 30 minutes in the USNS group (63.3% vs. 38.3%; P = 0.010). The postoperative pain score, the number of patients who required bolus local anesthetic and intravenous patient-controlled analgesia, and knee flexion on the second postoperative day were not significantly different between the two groups of patients.
CONCLUSIONS: Ultrasound-assisted placement of a stimulating catheter for femoral nerve blocks decreases the time necessary to perform the block compared with just the nerve-stimulating technique. In addition, a more complete blockade is achieved using the ultrasound-assisted technique.

Entities:  

Mesh:

Year:  2011        PMID: 21362274

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  2 in total

Review 1.  Ultrasound guidance for upper and lower limb blocks.

Authors:  Sharon R Lewis; Anastasia Price; Kevin J Walker; Ken McGrattan; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-09-11

2.  Minimum Effective Analgesic Concentration of Ropivacaine in Saphenous Block Guided by Ultrasound for Knee Arthroscopic Meniscectomy: Randomized, Double-Blind Study.

Authors:  Ed Carlos Rey Moura; Caio Marcio Barros de Oliveira; Plinio da Cunha Leal; Rioko Kimiko Sakata
Journal:  J Pain Res       Date:  2021-01-13       Impact factor: 3.133

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.