Literature DB >> 21361691

High-resolution resonant and nonresonant fiber-scanning confocal microscope.

Benno H W Hendriks1, Walter C J Bierhoff, Jeroen J L Horikx, Adrien E Desjardins, Cees A Hezemans, Gert W 't Hooft, Gerald W Lucassen, Nenad Mihajlovic.   

Abstract

We present a novel, hand-held microscope probe for acquiring confocal images of biological tissue. This probe generates images by scanning a fiber-lens combination with a miniature electromagnetic actuator, which allows it to be operated in resonant and nonresonant scanning modes. In the resonant scanning mode, a circular field of view with a diameter of 190 μm and an angular frequency of 127 Hz can be achieved. In the nonresonant scanning mode, a maximum field of view with a width of 69 μm can be achieved. The measured transverse and axial resolutions are 0.60 and 7.4 μm, respectively. Images of biological tissue acquired in the resonant mode are presented, which demonstrate its potential for real-time tissue differentiation. With an outer diameter of 3 mm, the microscope probe could be utilized to visualize cellular microstructures in vivo across a broad range of minimally-invasive procedures.

Entities:  

Mesh:

Year:  2011        PMID: 21361691     DOI: 10.1117/1.3534781

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  5 in total

1.  Compact and flexible raster scanning multiphoton endoscope capable of imaging unstained tissue.

Authors:  David R Rivera; Christopher M Brown; Dimitre G Ouzounov; Ina Pavlova; Demirhan Kobat; Watt W Webb; Chris Xu
Journal:  Proc Natl Acad Sci U S A       Date:  2011-10-17       Impact factor: 11.205

2.  In vivo imaging of unstained tissues using a compact and flexible multiphoton microendoscope.

Authors:  Christopher M Brown; David R Rivera; Ina Pavlova; Dimitre G Ouzounov; Wendy O Williams; Sunish Mohanan; Watt W Webb; Chris Xu
Journal:  J Biomed Opt       Date:  2012-04       Impact factor: 3.170

3.  Light Sheet Fluorescence Microscopy (LSFM).

Authors:  Michael W Adams; Andrew F Loftus; Sarah E Dunn; Matthew S Joens; James A J Fitzpatrick
Journal:  Curr Protoc Cytom       Date:  2015-01-05

Review 4.  Confocal endomicroscopy: instrumentation and medical applications.

Authors:  Joey M Jabbour; Meagan A Saldua; Joel N Bixler; Kristen C Maitland
Journal:  Ann Biomed Eng       Date:  2011-10-13       Impact factor: 3.934

5.  A non-resonant fiber scanner based on an electrothermally-actuated MEMS stage.

Authors:  Xiaoyang Zhang; Can Duan; Lin Liu; Xingde Li; Huikai Xie
Journal:  Sens Actuators A Phys       Date:  2015-09-01       Impact factor: 3.407

  5 in total