PURPOSE: Compton camera has been proposed as a potential imaging tool in astronomy, industry, homeland security, and medical diagnostics. Due to the inherent geometrical complexity of Compton camera data, image reconstruction of distributed sources can be ineffective and/or time-consuming when using standard techniques such as filtered backprojection or maximum likelihood-expectation maximization (ML-EM). In this article, the authors demonstrate a fast reconstruction of Compton camera data using a novel stochastic origin ensembles (SOE) approach based on Markov chains.
METHODS: During image reconstruction, the origins of the measured events are randomly assigned to locations on conical surfaces, which are the Compton camera analogs of lines-of-responses in PET. Therefore, the image is defined as an ensemble of origin locations of all possible event origins. During the course of reconstruction, the origins of events are stochastically moved and the acceptance of the new event origin is determined by the predefined acceptance probability, which is proportional to the change in event density. For example, if the event density at the new location is higher than in the previous location, the new position is always accepted. After several iterations, the reconstructed distribution of origins converges to a quasistationary state which can be voxelized and displayed.
RESULTS: Comparison with the list-mode ML-EM reveals that the postfiltered SOE algorithm has similar performance in terms of image quality while clearly outperforming ML-EM in relation to reconstruction time.
CONCLUSIONS: In this study, the authors have implemented and tested a new image reconstruction algorithm for the Compton camera based on the stochastic origin ensembles with Markov chains. The algorithm uses list-mode data, is parallelizable, and can be used for any Compton camera geometry. SOE algorithm clearly outperforms list-mode ML-EM for simple Compton camera geometry in terms of reconstruction time. The difference in computational time will be much larger when full Compton camera system model, including resolution recovery, is implemented and realistic Compton camera geometries are used. It was also shown in this article that while correctly reconstructing the relative distribution of the activity in the object, the SOE algorithm tends to underestimate the intensity values and increase variance in the images; improvements to the SOE reconstruction algorithm will be considered in future work.

Entities:  

Mesh:

Year:  2011        PMID: 21361211     DOI: 10.1118/1.3528170

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Feasibility Studies of a New Event Selection Method to Improve Spatial Resolution of Compton Imaging for Medical Applications.

Authors:  E Draeger; S Peterson; D Mackin; H Chen; S Beddar; J C Polf
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-05-10

2.  Reconstruction of multiple-pinhole micro-SPECT data using origin ensembles.

Authors:  Morgan C Lyon; Arkadiusz Sitek; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

3.  Resolution recovery for Compton camera using origin ensemble algorithm.

Authors:  A Andreyev; A Celler; I Ozsahin; A Sitek
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

4.  Data analysis in emission tomography using emission-count posteriors.

Authors:  Arkadiusz Sitek
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

5.  3D prompt gamma imaging for proton beam range verification.

Authors:  E Draeger; D Mackin; S Peterson; H Chen; S Avery; S Beddar; J C Polf
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

6.  Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy.

Authors:  Dennis Mackin; Steve Peterson; Sam Beddar; Jerimy Polf
Journal:  Phys Med Biol       Date:  2012-05-16       Impact factor: 3.609

7.  Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy.

Authors:  Zhiyang Yao; Yongshun Xiao; Zhiqiang Chen; Bo Wang; Qinhan Hou
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

Review 8.  Development and Applications of Compton Camera-A Review.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Ramila Parajuli; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2022-09-28       Impact factor: 3.847

9.  Improved iterative reconstruction method for Compton imaging using median filter.

Authors:  Makoto Sakai; Raj Kumar Parajuli; Yoshiki Kubota; Nobuteru Kubo; Mikiko Kikuchi; Kazuo Arakawa; Takashi Nakano
Journal:  PLoS One       Date:  2020-03-06       Impact factor: 3.240

10.  Time of flight dual photon emission computed tomography.

Authors:  Chih-Chieh Chiang; Chun-Chao Chuang; Yu-Ching Ni; Meei-Ling Jan; Keh-Shih Chuang; Hsin-Hon Lin
Journal:  Sci Rep       Date:  2020-11-11       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.