Assessing the hazard posed by sediments contaminated with hydrophobic organic compounds is difficult, because measuring the freely dissolved porewater concentrations of such low-solubility chemicals can be challenging, and estimating their sediment-water partition coefficients remains quite uncertain. We suggest that more accurate site assessments can be achieved by employing sampling devices in which polymers, with known polymer-water partition coefficients, are used to absorb the contaminants from the sediment. To demonstrate the current accuracy and limitations of this approach, we compared use of three polymers, polydimethylsiloxane, polyoxymethylene, and polyethylene, exposed to a single sediment in two modes, one in which they were exhaustively mixed (tumbled) with the sediment and the other in which they were simply inserted into a static bed (passive). Comparing porewater concentrations of specific polychlorinated biphenyl (PCB) congeners with results obtained using air bridges, we found the results for tumbled polymers agreed within 20%, and the passive sampling agreed within a factor of 2. In contrast, porewater estimates based on sediment concentrations normalized to f(OC)K(OC), the weight fraction of organic carbon times the organic-carbon normalized partition coefficient, averaged a factor of 7 too high. We also found good correlations of each polymer's uptake of the PCBs with bioaccumulation by the polychaete, Neanthes arenaceodentata. Future improvements of the passive sampling mode will require devices that equilibrate faster and/or have some means such as performance reference compounds to estimate mass transfer limitations for individual deployments.
Copyright © 2011 SETAC.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21360577     DOI: 10.1002/etc.510

Source DB:  PubMed          Journal:  Environ Toxicol Chem        ISSN: 0730-7268            Impact factor:   3.742


  21 in total

1.  Using performance reference compounds to compare mass transfer calibration methodologies in passive samplers deployed in the water column.

Authors:  Abigail S Joyce; Robert M Burgess
Journal:  Environ Toxicol Chem       Date:  2018-07-13       Impact factor: 3.742

2.  Performance of passive samplers for monitoring estuarine water column concentrations: 1. Contaminants of concern.

Authors:  Monique M Perron; Robert M Burgess; Eric M Suuberg; Mark G Cantwell; Kelly G Pennell
Journal:  Environ Toxicol Chem       Date:  2013-10       Impact factor: 3.742

3.  Uptake of hydrophobic organic compounds, including organochlorine pesticides, polybrominated diphenyl ethers, and perfluoroalkyl acids in fish and blue crabs of the lower Passaic River, New Jersey, USA.

Authors:  Mohammed A Khairy; Gregory O Noonan; Rainer Lohmann
Journal:  Environ Toxicol Chem       Date:  2019-02-19       Impact factor: 3.742

Review 4.  Evaluating Polymeric Sampling as a Tool for Predicting the Bioaccumulation of Polychlorinated Biphenyls by Fish and Shellfish.

Authors:  Stine N Schmidt; Robert M Burgess
Journal:  Environ Sci Technol       Date:  2020-08-04       Impact factor: 9.028

5.  Equilibrium Porewater Measurement of PCBs and PAHs Using Direct Water Extraction and Comparison with Passive Sampling.

Authors:  Songjing Yan; Mandar Bokare; Upal Ghosh
Journal:  Environ Sci Technol       Date:  2022-06-27       Impact factor: 11.357

Review 6.  Methods to assess bioavailability of hydrophobic organic contaminants: Principles, operations, and limitations.

Authors:  Xinyi Cui; Philipp Mayer; Jay Gan
Journal:  Environ Pollut       Date:  2012-10-16       Impact factor: 8.071

7.  Performance of passive samplers for monitoring estuarine water column concentrations: 2. Emerging contaminants.

Authors:  Monique M Perron; Robert M Burgess; Eric M Suuberg; Mark G Cantwell; Kelly G Pennell
Journal:  Environ Toxicol Chem       Date:  2013-07-19       Impact factor: 3.742

8.  Assessing organic contaminant fluxes from contaminated sediments following dam removal in an urbanized river.

Authors:  Mark G Cantwell; Monique M Perron; Julia C Sullivan; David R Katz; Robert M Burgess; John King
Journal:  Environ Monit Assess       Date:  2014-04-12       Impact factor: 2.513

9.  Cross Validation of Two Partitioning-Based Sampling Approaches in Mesocosms Containing PCB Contaminated Field Sediment, Biota, and Activated Carbon Amendment.

Authors:  Stine N Schmidt; Alice P Wang; Philip T Gidley; Allyson H Wooley; Guilherme R Lotufo; Robert M Burgess; Upal Ghosh; Loretta A Fernandez; Philipp Mayer
Journal:  Environ Sci Technol       Date:  2017-08-21       Impact factor: 9.028

10.  Sediment pore water distribution coefficients of PCB congeners in enriched black carbon sediment.

Authors:  Andres Martinez; Colin O'Sullivan; Danny Reible; Keri C Hornbuckle
Journal:  Environ Pollut       Date:  2013-08-23       Impact factor: 8.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.