A reliable radiographic measurement technique for extra-articular scapular fractures.

Jack Anavian1, Joseph M Conflitti, Gaurav Khanna, S Trent Guthrie, Peter A Cole.   

Abstract

BACKGROUND: Currently, neither well-defined nor standardized measurement techniques exist for assessing deformity of extra-articular scapular fractures. To properly evaluate these injuries, compare observations across studies, and make clinical decisions, a validated measurement protocol for evaluating scapular fractures is needed. QUESTIONS/PURPOSES: We describe techniques to quantitatively characterize extra-articular scapular fracture deformity; evaluate the reliability of these characterizations in plain film radiographs and CT scans; and determine potential differences in the characterization of the deformity between the two imaging modalities. PATIENTS AND METHODS: We evaluated injury radiographs and three-dimensional CT images of 45 patients with extra-articular scapular fracture. Techniques for measuring medial/lateral displacement, angulation, translation, glenopolar angle, and glenoid version were established and utilized in two trials, performed 6 weeks apart, by three observers. We determined descriptive statistics for each measurement parameter.
RESULTS: Interobserver reliability based upon interclass correlation coefficients ranged from 0.36 to 0.76 for radiographs and from 0.48 to 0.87 for three-dimensional CT. Intraobserver reliability using Pearson r coefficient ranged from 0.60 to 0.75 for radiographs and 0.64 to 0.89 for three-dimensional CT. Both individual and pooled measurements for angulation and glenopolar angle were higher on three-dimensional CT versus radiographs.
CONCLUSIONS: Our data suggest three-dimensional CT is more reliable than plain radiography in the assessment of scapula fracture displacement. Therefore, we believe this modality should be utilized if fracture deformity warrants surgical consideration and to adequately compare data across studies. LEVEL OF EVIDENCE: Level IV, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2011        PMID: 21360211      PMCID: PMC3210266          DOI: 10.1007/s11999-011-1820-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  26 in total

1.  Outcome of glenoid neck fractures.

Authors:  Alistair M Pace; Ranald Stuart; Harry Brownlow
Journal:  J Shoulder Elbow Surg       Date:  2005 Nov-Dec       Impact factor: 3.019

2.  The role of plain films and computed tomography in the evaluation of scapular neck fractures.

Authors:  Timothy R McAdams; Field T Blevins; Thomas P Martin; Thomas A DeCoster
Journal:  J Orthop Trauma       Date:  2002-01       Impact factor: 2.512

3.  Scapular neck fracture--the influence of permanent malalignment of the glenoid neck on clinical outcome.

Authors:  J Romero; P Schai; A B Imhoff
Journal:  Arch Orthop Trauma Surg       Date:  2001-06       Impact factor: 3.067

4.  Multidetector CT in shoulder fractures.

Authors:  Ville V Haapamaki; Martti J Kiuru; Seppo K Koskinen
Journal:  Emerg Radiol       Date:  2004-12

5.  The prevalence and significance of missed scapular fractures in blunt chest trauma.

Authors:  R D Harris; J H Harris
Journal:  AJR Am J Roentgenol       Date:  1988-10       Impact factor: 3.959

Review 6.  Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.

Authors:  Sean E Nork; David P Barei; Michael J Gardner; Thomas A Schildhauer; Keith A Mayo; Stephen K Benirschke
Journal:  J Orthop Trauma       Date:  2008-08       Impact factor: 2.512

7.  Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures.

Authors:  Clifford B Jones; Jonathan P Cornelius; Debra L Sietsema; James R Ringler; Terrence J Endres
Journal:  J Orthop Trauma       Date:  2009-09       Impact factor: 2.512

8.  The operative treatment of scapular fractures.

Authors:  F H Hardegger; L A Simpson; B G Weber
Journal:  J Bone Joint Surg Br       Date:  1984-11

9.  Displaced scapular fractures: indication and long-term results of open reduction and internal fixation.

Authors:  G Bauer; W Fleischmann; E Dussler
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

10.  Causes of delayed diagnosis of scapular fractures.

Authors:  Ayman M A Tadros; Karl Lunsjo; Jaunsz Czechowski; Fikri M Abu-Zidan
Journal:  Injury       Date:  2008-03       Impact factor: 2.586

View more
  13 in total

1.  The scapular glenopolar angle: standard values and side differences.

Authors:  Michal Tuček; Ondřej Naňka; Jozef Malík; Jan Bartoníček
Journal:  Skeletal Radiol       Date:  2014-08-13       Impact factor: 2.199

2.  Extra-articular scapular fractures: comparison of theoretical and actual treatment.

Authors:  Berdien Brandsema; Valentin Neuhaus; Gertraud Gradl; David C Ring
Journal:  Shoulder Elbow       Date:  2015-03-22

3.  Osteosynthesis of scapular fractures: a retrospective cohort study.

Authors:  Christian Michelitsch; Nina Kabelitz; Herman Frima; Method Kabelitz; Reinier Beks; Philipp F Stillhard; Christoph Sommer
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-07       Impact factor: 3.067

4.  A new surgical approach for the treatment of scapular glenoid fractures- Axillary approach: A single center case series.

Authors:  Weigang Lou; Jianming Chen; Ming Li; Ding Xu
Journal:  Ann Med Surg (Lond)       Date:  2022-06-21

5.  Postoperative Evaluation of Reduction Loss in Proximal Humeral Fractures: A Comparison of Plain Radiographs and Computed Tomography.

Authors:  Xiao-Yang Jia; Yan-Xi Chen; Min-Fei Qiang; Kun Zhang; Hao-Bo Li; Yu-Chen Jiang; Yi-Jie Zhang
Journal:  Orthop Surg       Date:  2017-05-30       Impact factor: 2.071

6.  Scapula fractures.

Authors:  Peter A Cole; Gil Freeman; Jonathan R Dubin
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

7.  Scapula fractures in complex shoulder injuries and floating shoulders: a classification based on displacement and instability.

Authors:  Jan Friederichs; Mario Morgenstern; Volker Bühren
Journal:  J Trauma Manag Outcomes       Date:  2014-11-07

8.  [Internal fixation of lateral and medial borders for displaced scapular body fractures via minimally invasive approach:results of 23 cases].

Authors:  Mingxuan Gao; Dejun Nie; Yanfeng Chang; Weiqiang Xie; Yue Wang; Xingyu Pu; Wei Zhang; Wenyuan Luo
Journal:  Zhejiang Da Xue Xue Bao Yi Xue Ban       Date:  2019-12-25

Review 9.  Scapula fractures: a review.

Authors:  David Limb
Journal:  EFORT Open Rev       Date:  2021-06-28

10.  Compared to X-ray, three-dimensional computed tomography measurement is a reproducible radiographic method for normal proximal humerus.

Authors:  Xiaoyang Jia; Yanxi Chen; Minfei Qiang; Kun Zhang; Haobo Li; Yuchen Jiang; Yijie Zhang
Journal:  J Orthop Surg Res       Date:  2016-07-15       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.