Literature DB >> 21360041

Monitoring particulate matter levels and climate conditions in a Greek sheep and goat livestock building.

Dimitris K Papanastasiou1, Dimitris Fidaros, Thomas Bartzanas, Constantinos Kittas.   

Abstract

Atmospheric pollutants from livestock operations influence air quality inside livestock buildings and the air exhausted from them. The climate that prevails inside the building affects human and animal health and welfare, as well as productivity, while emissions from the building contribute to environmental pollution. The aim of this study was to examine the variation of two climatic parameters (namely temperature and relative humidity) and the levels of particulate matter of different sizes (PM10-PM2.5-PM1), as well as the relationships between them, inside a typical Greek naturally ventilated livestock building that hosts mainly sheep. The concentration of particles was recorded during a 45-day period (27/11-10/1), while temperature and relative humidity were observed during an almost 1-year period. The analysis revealed that the variation of outdoor weather conditions significantly influenced the indoor environment, as temperature and relative humidity inside the building varied in accordance to the outside climate conditions. Temperature remained higher indoors than outdoors during the winter and extremely low values were not recorded inside the building. However, the tolerable relative humidity levels recommended by the International Commission of Agricultural Engineering (CIGR) were fulfilled only in 47% of the hours during the almost 1-year period that was examined. This fact indicates that although temperature was satisfactorily controlled, the control of relative humidity was deficient. The concentration of particulate matter was increased during the cold winter days due to poor ventilation. The maximum daily average value of PM10, PM2.5 and PM1 concentration equaled to 363, 61 and 30 μg/m(3) respectively. The concentration of the coarse particles was strongly influenced by the farming activities that were daily taking place in the building, the dust resuspension being considered as the dominant source. A significant part of the fine particles were secondary, which the production of could be attributed to an increase in relative humidity levels. It is concluded that measures have to be adopted in order to achieve sufficient ventilation and to reduce particulate matter levels.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21360041     DOI: 10.1007/s10661-011-1921-1

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  18 in total

Review 1.  Dust levels and control methods in poultry houses.

Authors:  H H Ellen; R W Bottcher; E von Wachenfelt; H Takai
Journal:  J Agric Saf Health       Date:  2000-11

2.  Reducing airborne pathogens, dust and Salmonella transmission in experimental hatching cabinets using an electrostatic space charge system.

Authors:  B W Mitchell; R J Buhr; M E Berrang; J S Bailey; N A Cox
Journal:  Poult Sci       Date:  2002-01       Impact factor: 3.352

Review 3.  Ecological effects of particulate matter.

Authors:  D A Grantz; J H B Garner; D W Johnson
Journal:  Environ Int       Date:  2003-06       Impact factor: 9.621

4.  Measurement, analysis, and modeling of fine particulate matter in eastern North Carolina.

Authors:  Stephen Goetz; Viney P Aneja; Yang Zhang
Journal:  J Air Waste Manag Assoc       Date:  2008-09       Impact factor: 2.235

5.  Short-term effects of ambient sulphur dioxide and particulate matter on mortality in 12 European cities: results from time series data from the APHEA project. Air Pollution and Health: a European Approach.

Authors:  K Katsouyanni; G Touloumi; C Spix; J Schwartz; F Balducci; S Medina; G Rossi; B Wojtyniak; J Sunyer; L Bacharova; J P Schouten; A Ponka; H R Anderson
Journal:  BMJ       Date:  1997-06-07

6.  Quality-assured measurements of animal building emissions: particulate matter concentrations.

Authors:  Albert J Heber; Teng-Teeh Lim; Ji-Qin Ni; Pei-Chun Tao; Amy M Schmidt; Jacek A Koziel; Steven J Hoff; Larry D Jacobson; Yuanhui Zhang; Gerald B Baughman
Journal:  J Air Waste Manag Assoc       Date:  2006-12       Impact factor: 2.235

7.  Measurement and analysis of the relationship between ammonia, acid gases, and fine particles in eastern North Carolina.

Authors:  Bok Haeng Baek; Viney P Aneja
Journal:  J Air Waste Manag Assoc       Date:  2004-05       Impact factor: 2.235

8.  Respiratory symptoms and airway obstruction in swine veterinarians: a persistent problem.

Authors:  C I Andersen; Susanna G Von Essen; L M Smith; J Spencer; Rika Jolie; Kelley J Donham
Journal:  Am J Ind Med       Date:  2004-10       Impact factor: 2.214

Review 9.  Environmental factors affecting the severity of pneumonia in pigs.

Authors:  S H Done
Journal:  Vet Rec       Date:  1991-06-22       Impact factor: 2.695

Review 10.  Airborne particulate matter and human health: toxicological assessment and importance of size and composition of particles for oxidative damage and carcinogenic mechanisms.

Authors:  Athanasios Valavanidis; Konstantinos Fiotakis; Thomais Vlachogianni
Journal:  J Environ Sci Health C Environ Carcinog Ecotoxicol Rev       Date:  2008 Oct-Dec       Impact factor: 3.781

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.