Abstract

The steady state response motion of a base excited cantilever beam with circular cross-section excited by a unidirectional displacement will fall along a straight line. However, achieving straight-line motion with a real cantilever beam of circular cross-section is difficult to accomplish. This is due to the fact that nonlinear effects, small deviations from circularity, asymmetric boundary conditions, and actuator cross coupling can induce whirling. The vast majority of previous work on cantilever beam whirling has focused on the effects of system nonlinearities. We show that whirling is a much broader problem in the design of resonant beam scanners in that the onset of whirling does not depend on large amplitude of motion. Rather, whirling is the norm in real systems due to small system asymmetries and actuator cross coupling. It is therefore necessary to control the growth of the whirling motion when a unidirectional beam motion is desired. We have developed a novel technique to identify the two eigen directions of the beam. Base excitation generated by virtual electrodes along these orthogonal eigen axes of the cantilever beam system generates tip vibration without whirl. This leads to accurate open loop control of the motion of the beam through the combined actuation of two pairs of orthogonally placed actuator electrodes.

Entities:  

Year:  2011        PMID: 21359102      PMCID: PMC3045204          DOI: 10.1016/j.jsv.2010.10.019

Source DB:  PubMed          Journal:  J Sound Vib        ISSN: 0022-460X            Impact factor:   3.655


  2 in total

1.  Tethered capsule endoscopy, a low-cost and high-performance alternative technology for the screening of esophageal cancer and Barrett's esophagus.

Authors:  Eric J Seibel; Robert E Carroll; Jason A Dominitz; Richard S Johnston; C David Melville; Cameron M Lee; Steven M Seitz; Michael B Kimmey
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

Review 2.  Scanning single fiber endoscopy: a new platform technology for integrated laser imaging, diagnosis, and future therapies.

Authors:  Eric J Seibel; Christopher M Brown; Jason A Dominitz; Michael B Kimmey
Journal:  Gastrointest Endosc Clin N Am       Date:  2008-07
  2 in total
  3 in total

1.  Run-to-Run Optimization Control Within Exact Inverse Framework for Scan Tracking.

Authors:  Ivan L Yeoh; Per G Reinhall; Martin C Berg; Howard J Chizeck; Eric J Seibel
Journal:  J Dyn Syst Meas Control       Date:  2017-06-05       Impact factor: 1.372

Review 2.  Scanning and Actuation Techniques for Cantilever-Based Fiber Optic Endoscopic Scanners-A Review.

Authors:  Mandeep Kaur; Pierre M Lane; Carlo Menon
Journal:  Sensors (Basel)       Date:  2021-01-02       Impact factor: 3.576

3.  Development of a real-time flexible multiphoton microendoscope for label-free imaging in a live animal.

Authors:  Guillaume Ducourthial; Pierre Leclerc; Tigran Mansuryan; Marc Fabert; Julien Brevier; Rémi Habert; Flavie Braud; Renaud Batrin; Christine Vever-Bizet; Geneviève Bourg-Heckly; Luc Thiberville; Anne Druilhe; Alexandre Kudlinski; Frédéric Louradour
Journal:  Sci Rep       Date:  2015-12-17       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.