Literature DB >> 21359015

Endovascular repair of thoracic aortic injury: current thoughts and technical considerations.

W Darrin Clouse1.   

Abstract

Thoracic aortic traumatic injury is a highly morbid event. Mortality and paraplegia rates after emergent open repair remain high. Now, however, thoracic aortic endografting for trauma (TAET) is commonly used. It is appealing due to reduction of operative stress for the multiply injured trauma victim. This minimizing of stress and risk is secondary to avoidance of thoracotomy, single-lung ventilation, aortic cross-clamping, and the more complex anesthetic techniques required. Early and midterm results from TAET delineate improved outcomes, yet access and aortic constraints continue to challenge TAET. Questions regarding longer-term durability of endografts in younger patients remain unanswered. Broader application of TAET within endovascular programs is challenged by appropriate imaging, operating suite inventories, and the logistics and personnel required for TAET. Currently developed thoracic endograft devices are not ideal for TAET due to platform size and graft diameter. This is changing, however, as new modifications have been developed and trials are ongoing. In light of these collective factors, the management paradigm for traumatic aortic injury is beginning to favor TAET.

Entities:  

Keywords:  Aortic trauma; endovascular repair; thoracic aortic repair; thoracic endografts

Year:  2010        PMID: 21359015      PMCID: PMC3036502          DOI: 10.1055/s-0030-1247889

Source DB:  PubMed          Journal:  Semin Intervent Radiol        ISSN: 0739-9529            Impact factor:   1.513


  72 in total

Review 1.  Technical strategies to expand stent-graft applicability in the aortic arch and proximal descending thoracic aorta.

Authors:  Frank J Criado; Marcos F Barnatan; Youssef Rizk; Nancy S Clark; Cecilia F Wang
Journal:  J Endovasc Ther       Date:  2002-06       Impact factor: 3.487

2.  Acute traumatic aortic rupture: a comparison of surgical and stent-graft repair.

Authors:  H Rousseau; C Dambrin; B Marcheix; L Richeux; M Mazerolles; C Cron; A Watkinson; A Mugniot; P Soula; V Chabbert; G Canevet; D Roux; P Massabuau; G Meites; T Tran Van; P Otal
Journal:  J Thorac Cardiovasc Surg       Date:  2005-05       Impact factor: 5.209

3.  Rapid ventricular pacing to lower blood pressure during endograft deployment in the thoracic aorta.

Authors:  Suwatchai Pornratanarangsi; Mark W I Webster; Peter Alison; Parma Nand
Journal:  Ann Thorac Surg       Date:  2006-05       Impact factor: 4.330

4.  Mid-term results of conservative, conventional and endovascular treatment for acute traumatic aortic lesions.

Authors:  P Stampfl; M Greitbauer; D Zimpfer; T Fleck; M Schoder; J Lammer; E Wolner; M Grimm; V Vécsei; M Czerny
Journal:  Eur J Vasc Endovasc Surg       Date:  2005-12-22       Impact factor: 7.069

5.  Twenty consecutive cases of endograft repair of traumatic aortic disruption: lessons learned.

Authors:  David G Neschis; Sina Moaine; Rao Gutta; Kirk Charles; Thomas M Scalea; William R Flinn; Bartley P Griffith
Journal:  J Vasc Surg       Date:  2007-01-24       Impact factor: 4.268

Review 6.  The COOK TX2 thoracic stent graft: preliminary experience and trial design.

Authors:  Heitham T Hassoun; Jon S Matsumura
Journal:  Semin Vasc Surg       Date:  2006-03       Impact factor: 1.000

Review 7.  Endovascular management of vascular trauma.

Authors:  Benjamin W Starnes; Zachary M Arthurs
Journal:  Perspect Vasc Surg Endovasc Ther       Date:  2006-06

8.  Traumatic rupture of the aorta: immediate or delayed repair?

Authors:  Panagiotis N Symbas; Andrew J Sherman; Jeffery M Silver; John D Symbas; Jodi J Lackey
Journal:  Ann Surg       Date:  2002-06       Impact factor: 12.969

9.  Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis.

Authors:  Michel S Makaroun; Ellen D Dillavou; Stephen T Kee; Gregorio Sicard; Elliot Chaikof; Joseph Bavaria; David Williams; Richard P Cambria; R Scott Mitchell
Journal:  J Vasc Surg       Date:  2005-01       Impact factor: 4.268

10.  Prospective study of blunt aortic injury: Multicenter Trial of the American Association for the Surgery of Trauma.

Authors:  T C Fabian; J D Richardson; M A Croce; J S Smith; G Rodman; P A Kearney; W Flynn; A L Ney; J B Cone; F A Luchette; D H Wisner; D J Scholten; B L Beaver; A K Conn; R Coscia; D B Hoyt; J A Morris; J D Harviel; A B Peitzman; R P Bynoe; D L Diamond; M Wall; J D Gates; J A Asensio; B L Enderson
Journal:  J Trauma       Date:  1997-03
View more
  2 in total

1.  The role of transesophageal echocardiography in endovascular repair of traumatic aortic transection.

Authors:  Madan Mohan Maddali; Sulaiman Saif Al-Shamsi; Said Abdelrahman Sabek; Mahmood Al-Hajri
Journal:  Oman Med J       Date:  2014-09

2.  Thoracic aortic transection resulting in a type B dissection following blunt trauma.

Authors:  Lance Fogleman; Terrell Caffery; Jeffrey Gruner; Danielle Tatum
Journal:  BMJ Case Rep       Date:  2017-11-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.