Literature DB >> 21358074

Monte Carlo and experimental dosimetric study of the mHDR-v2 brachytherapy source.

Rakesh M Chandola1, Samit Tiwari, Manoj K Kowar, Vivek Choudhary.   

Abstract

The conventional treatment planning system (TPS) gives analytical calculations with ± 15 to 20% dose, which may lead to over exposure of critical organs or under dose of target. It is to obtain dose distribution parameters of nucletron high dose rate (HDR) microselectron v2 (mHDR-v2) 192 Ir brachytherapy source by experiment and by calculated study using Monte Carlo (MC) EGSnrc code, and to find the similarity between them, and with any past study. To validate data, another MC GEANT4 study done in this work on the same source is also presented. Different software of the computer e.g. paint, excel, etc are employed for preparation of figures and graphs. The measured study of the source was done using an in-air ionization chamber, water phantom, and measurement set-up, while the calculated study was done by modeling the set up of the measured study by using the MC EGSnrc and GEANT4. Mean and probability are used in calculation of average values, and calculation of the uncertainties in result and discussion. The measured and calculated values of dose rate constant, radial dose function, and 2D anisotropy function were found to be in agreement with each other as well as with published data. The results of this study can be used as input to TPS.

Entities:  

Mesh:

Year:  2010        PMID: 21358074     DOI: 10.4103/0973-1482.77068

Source DB:  PubMed          Journal:  J Cancer Res Ther        ISSN: 1998-4138            Impact factor:   1.805


  3 in total

1.  Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

Authors:  Tarcisio Passos Ribeiro de Campos; Luciana Batista Nogueira; Bruno Trindade; Ethel Mizrahy Cuperschmid
Journal:  Rep Pract Oncol Radiother       Date:  2016-01-04

2.  A detailed Monte Carlo evaluation of 192Ir dose enhancement for gold nanoparticles and comparison with experimentally measured dose enhancements.

Authors:  Tara Gray; Nema Bassiri; Shaquan David; Devanshi Yogeshkumar Patel; Sotirios Stathakis; Neil Kirby; Kathryn M Mayer
Journal:  Phys Med Biol       Date:  2020-07-06       Impact factor: 3.609

3.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.