Literature DB >> 21358027

Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation.

Ying Chen1, Yang Song, Shaoxiang Zhang, Jianan Li, Changli Zhao, Xiaonong Zhang.   

Abstract

In this study, polycaprolactone (PCL) and polylactic acid (PLA) coatings were prepared on the surface of high purity magnesium (HPMs), respectively, and electrochemical and dynamic degradation tests were used to investigate the degradation behaviors of these polymer-coated HPMs. The experimental results indicated that two uniform and smooth polymer films with thicknesses between 15 and 20 µm were successfully prepared on the HPMs. Electrochemical tests showed that both PCL-coated and PLA-coated HPMs had higher free corrosion potentials (E(corr)) and smaller corrosion currents (I(corr)) in the modified simulated body fluid (m-SBF) at 37 °C, compared to those of the uncoated HPMs. Dynamic degradation tests simulating the flow conditions in coronary arteries were carried out on a specific test platform. The weight of the specimens and the pH over the tests were recorded to characterize the corrosion performance of those samples. The surfaces of the specimens after the dynamic degradation tests were also examined. The data implied that there was a special interaction between HPM and its polymer coatings during the dynamic degradation tests, which undermined the corrosion resistance of the coated HPMs. A model was proposed to illustrate the interaction between the polymer coatings and HPM. This study also suggested that this reciprocity may also exist on the implanted magnesium stents coated with biodegradable polymers, which is a potential obstacle for the further development of drug-eluting magnesium stents.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21358027     DOI: 10.1088/1748-6041/6/2/025005

Source DB:  PubMed          Journal:  Biomed Mater        ISSN: 1748-6041            Impact factor:   3.715


  12 in total

1.  Biodegradable Magnesium Alloys: A Review of Material Development and Applications.

Authors:  Dharam Persaud-Sharma; Anthony McGoron
Journal:  J Biomim Biomater Tissue Eng       Date:  2012-02-03

2.  Biodegradable poly(lactide-co-glycolide) coatings on magnesium alloys for orthopedic applications.

Authors:  Nicole J Ostrowski; Boeun Lee; Abhijit Roy; Madhumati Ramanathan; Prashant N Kumta
Journal:  J Mater Sci Mater Med       Date:  2012-10-10       Impact factor: 3.896

Review 3.  A review of current challenges and prospects of magnesium and its alloy for bone implant applications.

Authors:  Meysam Nasr Azadani; Abolfazl Zahedi; Oluwole Kingsley Bowoto; Bankole Ibrahim Oladapo
Journal:  Prog Biomater       Date:  2022-03-03

4.  Comparison of Selective Laser Melted Titanium and Magnesium Implants Coated with PCL.

Authors:  Julia Matena; Svea Petersen; Matthias Gieseke; Michael Teske; Martin Beyerbach; Andreas Kampmann; Hugo Murua Escobar; Nils-Claudius Gellrich; Heinz Haferkamp; Ingo Nolte
Journal:  Int J Mol Sci       Date:  2015-06-10       Impact factor: 5.923

5.  Osteointegration of Porous Poly-ε-Caprolactone-Coated and Previtalised Magnesium Implants in Critically Sized Calvarial Bone Defects in the Mouse Model.

Authors:  Michael Grau; Christian Seiler; Laura Roland; Julia Matena; Claudia Windhövel; Michael Teske; Hugo Murua Escobar; Matthias Lüpke; Hermann Seifert; Nils-Claudius Gellrich; Heinz Haferkamp; Ingo Nolte
Journal:  Materials (Basel)       Date:  2017-12-21       Impact factor: 3.623

6.  Enhanced corrosion resistance and cytocompatibility of biodegradable Mg alloys by introduction of Mg(OH)2 particles into poly (L-lactic acid) coating.

Authors:  Yong-Juan Shi; Jia Pei; Jian Zhang; Jia-Lin Niu; Hua Zhang; Sheng-Rong Guo; Zhong-Hua Li; Guang-Yin Yuan
Journal:  Sci Rep       Date:  2017-02-02       Impact factor: 4.379

7.  Photocrosslinkable Col/PCL/Mg composite membrane providing spatiotemporal maintenance and positive osteogenetic effects during guided bone regeneration.

Authors:  Feilong Wang; Dandan Xia; Siyi Wang; Ranli Gu; Fan Yang; Xiao Zhao; Xuenan Liu; Yuan Zhu; Hao Liu; Yongxiang Xu; Yunsong Liu; Yongsheng Zhou
Journal:  Bioact Mater       Date:  2021-11-03

Review 8.  Corrosion Behavior in Magnesium-Based Alloys for Biomedical Applications.

Authors:  Liming Xu; Xingwang Liu; Kang Sun; Rao Fu; Gang Wang
Journal:  Materials (Basel)       Date:  2022-04-01       Impact factor: 3.623

9.  Similarities and differences in coatings for magnesium-based stents and orthopaedic implants.

Authors:  Jun Ma; Marc Thompson; Nan Zhao; Donghui Zhu
Journal:  J Orthop Translat       Date:  2014-04-05       Impact factor: 5.191

10.  Improvement of osteogenesis by a uniform PCL coating on a magnesium screw for biodegradable applications.

Authors:  Yu-Kyoung Kim; Kwang-Bok Lee; Seo-Young Kim; Yong-Seok Jang; Jin Hyeok Kim; Min-Ho Lee
Journal:  Sci Rep       Date:  2018-09-05       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.