Literature DB >> 21357560

Assessment of global liver blood flow with quantitative dynamic contrast-enhanced ultrasound.

Thomas P Gauthier1, Harpreet S Wasan, Aun Muhammad, David R Owen, Edward L S Leen.   

Abstract

OBJECTIVES: This study assessed the potential of quantitative analysis of contrast bolus kinetics to reflect global liver blood flow.
METHODS: A dynamic contrast-enhanced ultrasound flow phantom was developed. A peristaltic pump established constant volume flow ranging between 16.5 and 49.5 mL/min (2-mm tube) and 85.5 and 256.5 mL/min (5-mm tube). After bolus injection of 2 doses of a contrast agent, a region of interest was drawn over the cross section of the tube used for a particular acquisition; the rise time, peak intensity, and wash-in slope were derived from time-intensity curves. Twenty healthy volunteers and 25 patients with biopsy-proven colorectal liver metastases were scanned with dynamic contrast-enhanced ultrasound. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Hepatic artery/portal vein ratios of the parameters were also calculated.
RESULTS: In the in vitro experiment, the rise time decreased while the peak intensity and wash-in slope increased with increasing volume flow for both tube diameters and contrast bolus volumes. In the clinical study, the rise time was lowered in the hepatic artery but elevated in the portal vein, and the peak intensity and wash-in slope were elevated in the hepatic artery but lowered in the portal vein in patients with colorectal liver metastases compared with healthy volunteers, although not in a statistically significant manner. This finding was consistent with an increase in hepatic artery blood flow, a decrease in portal vein blood flow, or both in patients with colorectal liver metastases compared with healthy volunteers. Only the 3 hepatic artery/portal vein ratios of the parameters achieved statistical significance in differentiating healthy volunteers from patients with colorectal liver metastases (P < .05).
CONCLUSIONS: Surrogate measurements of liver blood flow may be derived from quantitative analysis of dynamic contrast-enhanced ultrasound studies. They may have potential for quick and easy assessment of altered hepatic hemodynamics.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21357560     DOI: 10.7863/jum.2011.30.3.379

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Quantitative mapping of tumor vascularity using volumetric contrast-enhanced ultrasound.

Authors:  Kenneth Hoyt; Anna Sorace; Reshu Saini
Journal:  Invest Radiol       Date:  2012-03       Impact factor: 6.016

2.  Volumetric contrast-enhanced ultrasound imaging to assess early response to apoptosis-inducing anti-death receptor 5 antibody therapy in a breast cancer animal model.

Authors:  Kenneth Hoyt; Anna Sorace; Reshu Saini
Journal:  J Ultrasound Med       Date:  2012-11       Impact factor: 2.153

3.  Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.

Authors:  Anush Sridharan; John R Eisenbrey; Ji-Bin Liu; Priscilla Machado; Valgerdur G Halldorsdottir; Jaydev K Dave; Hongjia Zhao; Yu He; Suhyun Park; Scott Dianis; Kirk Wallace; Kai E Thomenius; Flemming Forsberg
Journal:  Invest Radiol       Date:  2013-09       Impact factor: 6.016

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.