Sound recording and digital phonocardiography of cardiac murmurs in dogs by using a sensor-based electronic stethoscope.

Károly Vörös1, Ingo Nolte, Stephan Hungerbühler, Jeno Reiczigel, Jan P Ehlers, Guy Tater, Reinhard Mischke, Tanja Zimmering, Matthias Schneider.   

Abstract

The goals of this study were to present a technique of digitalised sound recordings and phonocardiograms (dPCGs), and to analyse its diagnostic capabilities. Heart sounds of 20 dogs were auscultated in vivo (on-line) and recorded with dPCGs by two authors using a Welch Allyn Meditron Stethoscope System. Sound recordings were auscultated off-line and blindly by four different observers having various auscultatory experiences, then listened to while viewing dPCGs. The results were compared to echocardiographic diagnoses. There was a significant agreement (p < 0.001) between on-line and off-line auscultatory findings regarding the four observers, ranging from 45% to 75% (weighted kappa values: 0.72 to 0.87). The best agreement was achieved by Observer 1 having the highest experience. Significant differences (p < 0.05) were found between Observer 1 and Observer 4 (with the lowest experience) in judging the quality of the murmurs during the off-line and blind auscultation. However, there were only minimal differences (95% to 100% agreements) in dPCG analyses among the four observers regarding intensity and quality of the murmurs while simultaneously listening to and viewing the dPCGs. Significant correlations were found between the traditional '0 to 6 scale' and a new '0 to 3 scale' murmur intensity gradings by all observers (correlation coefficients 0.640 to 0.908; p < 0.01 to p < 0.001). Analysis of dPCGs might be a valuable, additional tool helping with the diagnosis of canine cardiac murmurs, especially for those with less cardiological experience.

Entities:  

Mesh:

Year:  2011        PMID: 21354939     DOI: 10.1556/AVet.59.2011.1.3

Source DB:  PubMed          Journal:  Acta Vet Hung        ISSN: 0236-6290            Impact factor:   0.955


  3 in total

1.  Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission.

Authors:  Kyoung Hoon Lim; Young Duck Shin; Sang Hi Park; Jin Ho Bae; Hong Jae Lee; Seon Jung Kim; Ji Yun Shin; Young Jin Choi
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

2.  Stretchable Composite Acoustic Transducer for Wearable Monitoring of Vital Signs.

Authors:  Yasin Cotur; Michael Kasimatis; Matti Kaisti; Selin Olenik; Charis Georgiou; Fira Güder
Journal:  Adv Funct Mater       Date:  2020-02-25       Impact factor: 18.808

3.  Use of proposed systolic and myocardial performance indices derived from simultaneous ECG and PCG recordings to assess cardiac function in healthy Beagles.

Authors:  Karlo Romano B Gicana; Chirutchaya Pinidmontree; Kitchanan Kosalathip; Siraphop Sirirut; Siripen Komolvanich; Sariya Asawakarn; Walasinee Sakcamduang; Phornphop Naiyanetr; Kittipong Tachampa
Journal:  Vet World       Date:  2022-07-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.