Literature DB >> 21353419

Iodine removal in intravenous dual-energy CT-cholangiography: is virtual non-enhanced imaging effective to replace true non-enhanced imaging?

Christof M Sommer1, Christoph B Schwarzwaelder, Wolfram Stiller, Sebastian T Schindera, Ulrike Stampfl, Nadine Bellemann, Maria Holzschuh, Jan Schmidt, Juergen Weitz, Lars Grenacher, Hans U Kauczor, Boris A Radeleff.   

Abstract

PURPOSE: To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography.
MATERIALS AND METHODS: From April 2009 until February 2010, fifteen potential donors for living-related liver transplantation (mean age 37.6±10.8 years) were included. Potential donors underwent a two-phase CT-examination of the liver. The first phase consisted of a single-energy non-enhanced CT-acquisition that provided TNI. After administration of hepatobiliary contrast agent, the second phase was performed as a dual-energy cholangiographic CT-acquisition. This provided VNI. Objective image quality (attenuation values [bile ducts and liver parenchyma] and contrast-to-noise ratio) and subjective overall image quality (1 - excellent; 5 - non diagnostic) were evaluated. Effective radiation dose was compared.
RESULTS: For TNI and VNI, attenuation values for bile ducts were 16.8±11.2HU and 5.5±17.0HU (p<0.05) and for liver parenchyma 55.3±8.4HU and 58.1±10.6HU (n.s.). For TNI and VNI, contrast-to-noise ratio was 2.6±0.6HU and 6.9±2.1HU (p<0.001). For VNI, subjective overall image quality was 1 in ten datasets, 2 in four datasets and 3 in one dataset. Effective radiation dose for the dual-energy cholangiographic CT-acquisition was 3.6±0.9mSv and for two-phase single-energy CT-cholangiography 5.1±1.3mSv (p<0.001).
CONCLUSION: In this study on iodine removal in intravenous dual-energy CT-cholangiography, subjective image quality is equivalent, contrast-to-noise ratio is improved and effective radiation dose is reduced when VNI is performed. The differences between TNI and VNI with respect to attenuation values seem to have limited clinical relevance and therefore we consider VNI as effective to replace TNI.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21353419     DOI: 10.1016/j.ejrad.2011.01.087

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

Review 1.  Dual-energy computed tomography applications in uroradiology.

Authors:  Jong Park; Hersh Chandarana; Michael Macari; Alec J Megibow
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

2.  Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization.

Authors:  Joseph Harms; Tonghe Wang; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams.

Authors:  Usman Mahmood; Natally Horvat; Joao Vicente Horvat; Davinia Ryan; Yiming Gao; Gabriella Carollo; Rommel DeOcampo; Richard K Do; Seth Katz; Scott Gerst; C Ross Schmidtlein; Lawrence Dauer; Yusuf Erdi; Lorenzo Mannelli
Journal:  Eur J Radiol       Date:  2018-02-19       Impact factor: 3.528

4.  Noise Suppression for Dual-Energy CT Through Entropy Minimization.

Authors:  Michael Petrongolo; Lei Zhu
Journal:  IEEE Trans Med Imaging       Date:  2015-05-01       Impact factor: 10.048

5.  Patient Comfort in Modern Computed Tomography: What Really Counts.

Authors:  Julius Henning Niehoff; Andreas Heuser; Arwed Elias Michael; Simon Lennartz; Jan Borggrefe; Jan Robert Kroeger
Journal:  Tomography       Date:  2022-05-23

6.  Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study.

Authors:  Shi-Feng Tian; Ai-Lian Liu; Jing-Hong Liu; Mei-Yu Sun; He-Qing Wang; Yi-Jun Liu
Journal:  Chin Med J (Engl)       Date:  2015-03-05       Impact factor: 2.628

7.  Renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kVp images obtained during the same CT examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction.

Authors:  Yoshitake Yamada; Minoru Yamada; Koichi Sugisawa; Hirotaka Akita; Eisuke Shiomi; Takayuki Abe; Shigeo Okuda; Masahiro Jinzaki
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

8.  Radiotherapy treatment planning with contrast-enhanced computed tomography: feasibility of dual-energy virtual unenhanced imaging for improved dose calculations.

Authors:  Sachiko Yamada; Takashi Ueguchi; Toshiyuki Ogata; Hirokazu Mizuno; Ryota Ogihara; Masahiko Koizumi; Takeshi Shimazu; Kenya Murase; Kazuhiko Ogawa
Journal:  Radiat Oncol       Date:  2014-07-29       Impact factor: 3.481

9.  Virtual Non-Contrast versus True Non-Contrast Computed Tomography: Initial Experiences with a Photon Counting Scanner Approved for Clinical Use.

Authors:  Julius Henning Niehoff; Matthias Michael Woeltjen; Kai Roman Laukamp; Jan Borggrefe; Jan Robert Kroeger
Journal:  Diagnostics (Basel)       Date:  2021-12-16
  9 in total