Literature DB >> 21350092

Erythrocyte sedimentation rate (ESR) measured by the Streck ESR-Auto Plus is higher than with the Sediplast Westergren method: a validation study.

Bharathi Vennapusa1, Laura De La Cruz, Hemangini Shah, Veronica Michalski, Qian-Yun Zhang.   

Abstract

The erythrocyte sedimentation rate (ESR) is a nonspecific indicator of disease activity and is often used by clinicians in assisting diagnosis and follow-up of many inflammatory disorders. The Westergren method is considered the standard method for measuring ESR. Recently, many automated instruments have become available to address laboratory safety and time efficiency. We validated the Streck ESR-Auto Plus instrument (Streck, Omaha, NE) using the Sediplast (Polymedco, Cortlandt Manor, NY) Westergren method as the reference method. Blood samples collected in 113 EDTA tubes were transferred into Sediplast vials and Streck high-altitude vacuum tubes for measuring the ESR. There was good correlation between the Sediplast and Streck methods (0.95) using Pearson correlation. The y-intercept was at 6.5 using linear regression, indicating systematic bias with a mean difference of 7.13 using the t test (P < .0001). We modified our reference ranges to rectify the systematic bias found during validation.

Entities:  

Mesh:

Year:  2011        PMID: 21350092     DOI: 10.1309/AJCP48YXBDGTGXEV

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.

Authors:  Elise Schapkaitz; Shilla RabuRabu; Marcel Engelbrecht
Journal:  J Clin Lab Anal       Date:  2018-08-26       Impact factor: 2.352

2.  Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.

Authors:  Cigdem Sonmez; Ozlem Ceylan Dogan; Aysegul Ozturk Kaymak; Nedim Akkaya; Kadir Okhan Akin; Gulcan Guntas
Journal:  J Clin Lab Anal       Date:  2018-01-17       Impact factor: 2.352

3.  Performance evaluation of the BC-720 auto hematology analyzer and establishment of the reference intervals of erythrocyte sedimentation rate in healthy adults.

Authors:  Guofang Shu; Rui Ding; Rong Ding; Zhi He; Yimin Shen; Dongmei Liu; Zhaohui Duan
Journal:  Ann Transl Med       Date:  2022-09

4.  Incorporating geographical factors with artificial neural networks to predict reference values of erythrocyte sedimentation rate.

Authors:  Qingsheng Yang; Kevin M Mwenda; Miao Ge
Journal:  Int J Health Geogr       Date:  2013-03-12       Impact factor: 3.918

  4 in total