Literature DB >> 21349465

Vasomotor function after paclitaxel-coated balloon post-dilation in porcine coronary stent model.

Takamitsu Nakamura1, Brigitta C Brott, Irena Brants, Deepal Panchal, Jinsheng Li, Jack P Chen, Spencer B King, Nicolas Chronos, Dongming Hou.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate endothelial function after post-dilation of bare-metal stents with paclitaxel-coated balloons (PCB) or non-drug-coated balloons (non-DCB) in a porcine model.
BACKGROUND: DCB are an attractive alternative to drug-eluting stents because they provide short duration of drug exposure, while potentially inhibiting in-stent restenosis. Drug-eluting stents are associated with impaired endothelial function. It is unknown whether this abnormal vasomotor function is mitigated by reduced duration of drug exposure.
METHODS: Thirteen pigs underwent bare-metal stent implantation (arteries, n = 30), followed by post-dilation with either PCB (SeQuent Please, B. Braun Melsungen AG, Berlin, Germany) (n = 17) or non-DCB (n = 13). Five pigs with unstented arteries (n = 14) were controls. Coronary vasomotion was assessed 1 month after stent implantation, using acetylcholine (Ach) and nitroglycerin. Measurements were obtained for distal segments.
RESULTS: Angiographic late loss and histological area stenosis were similar between PCB and non-DCB. However, the percentage of diameter change in response to Ach was diminished with PCB (p < 0.05), when compared with either non-DCB or naive arteries. There was no difference between non-DCB and naive arteries. Inflammatory score and intramural fibrin grading were significantly greater in PCB than non-DCB (p < 0.05). Additionally, inflammatory cell infiltration in the stented segments correlated with the degree of percentage of diameter change in response to Ach, at distal regions.
CONCLUSIONS: Post-dilation of bare-metal stents with PCB was associated with impaired vasodilatory response to Ach distal to the treated segments. Vasodilatory response after post-dilation with non-DCB was similar to control arteries.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21349465     DOI: 10.1016/j.jcin.2010.08.028

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  3 in total

1.  No-reflow phenomenon during treatment of coronary in-stent restenosis with a Paclitaxel-coated balloon catheter.

Authors:  Han-Hee Chung; Keon-Woong Moon; Mi-Hyang Jung; Hae-Kyung Yang; Kyung-Seon Park; Ki-Dong Yoo
Journal:  Korean Circ J       Date:  2012-06-28       Impact factor: 3.243

Review 2.  Macromolecular approaches to prevent thrombosis and intimal hyperplasia following percutaneous coronary intervention.

Authors:  Rebecca A Scott; Alyssa Panitch
Journal:  Biomacromolecules       Date:  2014-07-08       Impact factor: 6.988

Review 3.  Applying Principles of Regenerative Medicine to Vascular Stent Development.

Authors:  Prakash Parthiban Selvakumar; Michael Scott Rafuse; Richard Johnson; Wei Tan
Journal:  Front Bioeng Biotechnol       Date:  2022-03-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.