Literature DB >> 21348028

Use of the volar fixed angle plate for comminuted distal radius fractures and augmentation with a hydroxyapatite bone graft substitute.

Akira Goto1, Tsuyoshi Murase, Kunihiro Oka, Hideki Yoshikawa.   

Abstract

Treatment of distal radius fractures with a volar fixed angle plate achieves sufficient stabilisation and permits early physical exercise. However, secondary displacement after surgery sometimes occurs in elderly patients with a metaphyseal comminution and/or cases in which the subchondral support pegs were not placed immediately below the subchondral zone. We treated elderly patients suffering from distal radius fractures with metaphyseal comminution, using both volar fixed angle plate with or without augmentation with a hydroxyapatite bone graft substitute to investigate the benefit of augmentation for maintaining a fracture reduction. We evaluated the differences among radiographic parameters including palmar tilt, radial inclination, and ulnar variance on immediate postoperative and final follow-up radiographs to analyse the maintenance of the initial reduction. There were no significant differences between the two groups in terms of palmar tilt (P = 0.80) and radial inclination (P = 0.17); however, ulnar variance increased significantly in the group treated with a volar fixed angle plate without augmentation (P < 0.05). It might be useful to use a combination technique of a locking plate system and the hydroxyapatite bone graft substitute as augmentation to treat distal radius comminuted fractures in elderly patients.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21348028     DOI: 10.1142/S0218810411005023

Source DB:  PubMed          Journal:  Hand Surg        ISSN: 0218-8104


  4 in total

1.  Bone substitutes and implantation depths for subchondral bone repair in osteochondral defects of porcine knee joints.

Authors:  Tomohiko Matsuo; Keisuke Kita; Tatsuo Mae; Yasukazu Yonetani; Satoshi Miyamoto; Hideki Yoshikawa; Ken Nakata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-01       Impact factor: 4.342

Review 2.  The use of bone grafts and substitutes in the treatment of distal radius fractures.

Authors:  Kagan Ozer; Kevin C Chung
Journal:  Hand Clin       Date:  2012-03-27       Impact factor: 1.907

Review 3.  Ceramic and non-ceramic hydroxyapatite as a bone graft material: a brief review.

Authors:  S R Dutta; D Passi; P Singh; A Bhuibhar
Journal:  Ir J Med Sci       Date:  2014-11-27       Impact factor: 1.568

4.  Elderly unstable distal radius fractures a prospective cohort study of bone substitutes-augmented percutaneous pinning.

Authors:  Amr Abdel-Mordy Kandeel
Journal:  BMC Musculoskelet Disord       Date:  2022-03-12       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.