Literature DB >> 21347958

Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.

Jennifer M Thomasen1, Kenneth W Fent, Carolyn Reeb-Whitaker, Stephen G Whittaker, Leena A Nylander-French.   

Abstract

This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3-1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2-3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the sampler's ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during automotive spray painting.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21347958     DOI: 10.1080/15459624.2011.555711

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  2 in total

1.  Isocyanates and work-related asthma: Findings from California, Massachusetts, Michigan, and New Jersey, 1993-2008.

Authors:  Daniel Lefkowitz; Elise Pechter; Kathleen Fitzsimmons; Margaret Lumia; Alicia C Stephens; Letitia Davis; Jennifer Flattery; Justine Weinberg; Robert J Harrison; Mary Jo Reilly; Margaret S Filios; Gretchen E White; Kenneth D Rosenman
Journal:  Am J Ind Med       Date:  2015-09-09       Impact factor: 2.214

2.  Reaction products of hexamethylene diisocyanate vapors with "self" molecules in the airways of rabbits exposed via tracheostomy.

Authors:  Adam V Wisnewski; Jean Kanyo; Jennifer Asher; James A Goodrich; Grace Barnett; Lyn Patrylak; Jian Liu; Carrie A Redlich; Ala F Nassar
Journal:  Xenobiotica       Date:  2017-06-01       Impact factor: 1.908

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.