Acceleration of motion-compensated PET reconstruction: ordered subsets-gates EM algorithms and a priori reference gate information.

N Dikaios1, T D Fryer.   

Abstract

Patient motion during positron emission tomography scans leads to significant resolution loss and image degradation. Motion-compensated image reconstruction (MCIR) algorithms have proven to be reliable correction methods given accurate deformation fields. However, although ordered subsets (OS) are widely used to speed up the convergence, OS-MCIR algorithms are still computationally expensive. This study concentrates on acceleration of OS-MCIR algorithms through two methods: combining OS with motion subsets and use of an initial estimate based on reference gate data. These approaches were compared to two existing OS-MCIR algorithms and post-reconstruction registration using data from the NCAT phantom. The methods were evaluated in terms of noise, lesion bias and contrast-to-noise ratio (CNR). The straightforward combination of motion subsets with projection subsets (OSGEM) produced inferior results (lower CNR, p < 0.01) to existing OS-MCIR algorithms. The addition of a spacer step using data from all gates to OSGEM resulted in an algorithm (SS-OSGEM) that generated images that were statistically consistent with those from existing OS-MCIR algorithms (no significant difference in CNR, p > 0.05) at one third of the computational expense. The use of a reference gate initial estimate (MCDOi) resulted in comparable image quality in terms of bias and CNR (p > 0.05) at half the computational burden. This study indicates that MCDOi and SS-OSGEM in particular are attractive accelerated OS-MCIR approaches.

Entities:  

Mesh:

Year:  2011        PMID: 21346272     DOI: 10.1088/0031-9155/56/6/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  4D numerical observer for lesion detection in respiratory-gated PET.

Authors:  Auranuch Lorsakul; Quanzheng Li; Cathryn M Trott; Christopher Hoog; Yoann Petibon; Jinsong Ouyang; Andrew F Laine; Georges El Fakhri
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

Review 3.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.