Literature DB >> 21345250

Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastance.

Michael R Pinsky1.   

Abstract

Assessment of vasomotor tone is essential in defining appropriate resuscitation strategies for the hypotensive patient. Although changes in mean arterial pressure to cardiac output define arterial resistance, resistance is only one component of vasomotor tone. Compliance is the other component. The reciprocal of compliance is arterial elastance (Ea). Importantly, dynamic Ea can be estimated by the pulse pressure variation to stroke volume variation relation. Dynamic Ea is only one component of vasomotor tone, however, and increases in pulse pressure may not be proportional to increases in mean arterial pressure. Also, devices that use the arterial pressure pulse to calculate the stroke volume have an inherent bias that is different amongst devices based on their transfer function algorithms. The use of dynamic Ea for clinical decision-making thus needs to be validated separately for different devices and types of patients.

Entities:  

Mesh:

Year:  2011        PMID: 21345250      PMCID: PMC3222075          DOI: 10.1186/cc9986

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


  8 in total

1.  The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients.

Authors:  Mehrnaz Hadian; Donald A Severyn; Michael R Pinsky
Journal:  J Crit Care       Date:  2010-10-30       Impact factor: 3.425

2.  The measurement of the stroke volume from the pressure pulse.

Authors:  W F HAMILTON; J W REMINGTON
Journal:  Am J Physiol       Date:  1947-01

3.  Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans.

Authors:  D Chemla; J L Hébert; C Coirault; K Zamani; I Suard; P Colin; Y Lecarpentier
Journal:  Am J Physiol       Date:  1998-02

4.  Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP.

Authors:  F Michard; D Chemla; C Richard; M Wysocki; M R Pinsky; Y Lecarpentier; J L Teboul
Journal:  Am J Respir Crit Care Med       Date:  1999-03       Impact factor: 21.405

5.  Effective arterial elastance as index of arterial vascular load in humans.

Authors:  R P Kelly; C T Ting; T M Yang; C P Liu; W L Maughan; M S Chang; D A Kass
Journal:  Circulation       Date:  1992-08       Impact factor: 29.690

6.  Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients.

Authors:  Xavier Monnet; Mario Rienzo; David Osman; Nadia Anguel; Christian Richard; Michael R Pinsky; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2005-07-30       Impact factor: 17.440

7.  Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters.

Authors:  Mehrnaz Hadian; Hyung Kook Kim; Donald A Severyn; Michael R Pinsky
Journal:  Crit Care       Date:  2010-11-23       Impact factor: 9.097

8.  Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Manuel Gracia Romero
Journal:  Crit Care       Date:  2011-01-12       Impact factor: 9.097

  8 in total
  4 in total

1.  Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock.

Authors:  Pierre-Grégoire Guinot; Eugénie Bernard; Mélanie Levrard; Hervé Dupont; Emmanuel Lorne
Journal:  Crit Care       Date:  2015-01-19       Impact factor: 9.097

2.  Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study.

Authors:  Manuel Ignacio Monge García; Manuel Gracia Romero; Anselmo Gil Cano; Hollmann D Aya; Andrew Rhodes; Robert Michael Grounds; Maurizio Cecconi
Journal:  Crit Care       Date:  2014-11-19       Impact factor: 9.097

Review 3.  Effective hemodynamic monitoring.

Authors:  Michael R Pinsky; Maurizio Cecconi; Michelle S Chew; Daniel De Backer; Ivor Douglas; Mark Edwards; Olfa Hamzaoui; Glenn Hernandez; Greg Martin; Xavier Monnet; Bernd Saugel; Thomas W L Scheeren; Jean-Louis Teboul; Jean-Louis Vincent
Journal:  Crit Care       Date:  2022-09-28       Impact factor: 19.334

Review 4.  The meaning of blood pressure.

Authors:  S Magder
Journal:  Crit Care       Date:  2018-10-11       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.