Literature DB >> 21344833

Nanoleakage and microtensile bond strength at the adhesive-dentin interface after different etching times.

San-Jun Zhao1, Ling Zhang, Li-Hui Tang, Ji-Hua Chen.   

Abstract

PURPOSE: To evaluate the effect of etching time on the nanoleakage and microtensile bond strength (microTBS) at the interface between etch-and-rise adhesives and dentin.
METHODS: Eighty molars were sectioned to expose the superficial dentin and randomly divided into four groups according to the adhesives used: OptiBond Solo (OB), Single Bond (SB), One-Step (OS), and Prime&Bond NT (PB). Within each group, a total-etching technique was applied, and the dentin surfaces were etched for 0, 15, 30 or 60 seconds. Each treated tooth was then sectioned into sticks. A non-trimming microTBS test and TEM observation for nanoleakage were sequentially performed.
RESULTS: The degree of nanoleakage increased as etching time increased (P < 0.05). For the OS and PB groups, the highest microTBS values were achieved with 15 seconds of etching, followed by 30, 60 and 0 seconds. For the OB and SB groups, the microTBS values for 15- and 30-second etching times were similar and were both significantly higher than those of 0 and 60 seconds (P < 0.05).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21344833

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  1 in total

1.  Comparison of the Shear Bond Strength of Silorane-Based Composite Resin and Methacrylate Based Composite Resin to MTA.

Authors:  Buse Ayse Serin; Muharrem Cem Dogan; Hamdi Oguz Yoldas
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.