Literature DB >> 21339724

Recapitulation of an ion channel IV curve using frequency components.

John R Rigby1, Steven Poelzing.   

Abstract

INTRODUCTION: Presently, there are no established methods to measure multiple ion channel types simultaneously and decompose the measured current into portions attributable to each channel type. This study demonstrates how impedance spectroscopy may be used to identify specific frequencies that highly correlate with the steady state current amplitude measured during voltage clamp experiments. The method involves inserting a noise function containing specific frequencies into the voltage step protocol. In the work presented, a model cell is used to demonstrate that no high correlations are introduced by the voltage clamp circuitry, and also that the noise function itself does not introduce any high correlations when no ion channels are present. This validation is necessary before the technique can be applied to preparations containing ion channels. The purpose of the protocol presented is to demonstrate how to characterize the frequency response of a single ion channel type to a noise function. Once specific frequencies have been identified in an individual channel type, they can be used to reproduce the steady state current voltage (IV) curve. Frequencies that highly correlate with one channel type and minimally correlate with other channel types may then be used to estimate the current contribution of multiple channel types measured simultaneously.
METHODS: Voltage clamp measurements were performed on a model cell using a standard voltage step protocol (-150 to +50 mV, 5mV steps). Noise functions containing equal magnitudes of 1-15 kHz frequencies (zero to peak amplitudes: 50 or 100mV) were inserted into each voltage step. The real component of the Fast Fourier transform (FFT) of the output signal was calculated with and without noise for each step potential. The magnitude of each frequency as a function of voltage step was correlated with the current amplitude at the corresponding voltages. RESULTS AND
CONCLUSIONS: In the absence of noise (control), magnitudes of all frequencies except the DC component correlated poorly (|R|<0.5) with the IV curve, whereas the DC component had a correlation coefficient greater than 0.999 in all measurements. The quality of correlation between individual frequencies and the IV curve did not change when a noise function was added to the voltage step protocol. Likewise, increasing the amplitude of the noise function also did not increase the correlation. Control measurements demonstrate that the voltage clamp circuitry by itself does not cause any frequencies above 0 Hz to highly correlate with the steady-state IV curve. Likewise, measurements in the presence of the noise function demonstrate that the noise function does not cause any frequencies above 0 Hz to correlate with the steady-state IV curve when no ion channels are present. Based on this verification, the method can now be applied to preparations containing a single ion channel type with the intent of identifying frequencies whose amplitudes correlate specifically with that channel type.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21339724      PMCID: PMC3197388          DOI: 10.3791/2361

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  17 in total

1.  Frequency response of alternating currents through the Staphylococcus aureus alpha-hemolysin ion channel.

Authors:  M Misakian; J J Kasianowicz; B Robertson; O Petersons
Journal:  Bioelectromagnetics       Date:  2001-10       Impact factor: 2.010

2.  muI Na+ channels expressed transiently in human embryonic kidney cells: biochemical and biophysical properties.

Authors:  C Ukomadu; J Zhou; F J Sigworth; W S Agnew
Journal:  Neuron       Date:  1992-04       Impact factor: 17.173

3.  Quantitative description of three modes of activity of fast chloride channels from rat skeletal muscle.

Authors:  A L Blatz; K L Magleby
Journal:  J Physiol       Date:  1986-09       Impact factor: 5.182

4.  Positive feedback by a potassium-selective inward rectifier enhances tuning in vertebrate hair cells.

Authors:  M B Goodman; J J Art
Journal:  Biophys J       Date:  1996-07       Impact factor: 4.033

5.  Comparison of potassium currents in rabbit atrial and ventricular cells.

Authors:  W R Giles; Y Imaizumi
Journal:  J Physiol       Date:  1988-11       Impact factor: 5.182

6.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches.

Authors:  O P Hamill; A Marty; E Neher; B Sakmann; F J Sigworth
Journal:  Pflugers Arch       Date:  1981-08       Impact factor: 3.657

7.  Mechanism of potassium-channel selectivity revealed by Na(+) and Li(+) binding sites within the KcsA pore.

Authors:  Ameer N Thompson; Ilsoo Kim; Timothy D Panosian; Tina M Iverson; Toby W Allen; Crina M Nimigean
Journal:  Nat Struct Mol Biol       Date:  2009-11-29       Impact factor: 15.369

8.  Inward rectifier K+-channel kinetics from analysis of the complex conductance of Aplysia neuronal membrane.

Authors:  H Hayashi; H M Fishman
Journal:  Biophys J       Date:  1988-05       Impact factor: 4.033

9.  Physiological properties of hERG 1a/1b heteromeric currents and a hERG 1b-specific mutation associated with Long-QT syndrome.

Authors:  Harinath Sale; Jinling Wang; Thomas J O'Hara; David J Tester; Pallavi Phartiyal; Jia-Qiang He; Yoram Rudy; Michael J Ackerman; Gail A Robertson
Journal:  Circ Res       Date:  2008-09-05       Impact factor: 17.367

10.  Mechanism of calcium channel blockade by verapamil, D600, diltiazem and nitrendipine in single dialysed heart cells.

Authors:  K S Lee; R W Tsien
Journal:  Nature       Date:  1983-04-28       Impact factor: 49.962

View more