Literature DB >> 21338061

Simultaneous detection of multiple biomarkers with over three orders of concentration difference using phase change nanoparticles.

Chaoming Wang1, Zhaoyong Sun, Liyuan Ma, Ming Su.   

Abstract

A big challenge for multiplexed detection of cancer biomarkers is that biomarker concentrations in body fluid differs several orders of magnitude. Existing techniques are not suitable to detect low- and high-concentration biomarkers (protein and DNA) at the same time, and liquid chromatography or electrophoresis is used to separate or purify target biomarkers before analysis. This paper describes a new broad-range biomarker assay using solid to liquid phase change nanoparticles, where a panel of metallic nanoparticles (i.e., metals and eutectic alloys) are modified with a panel of ligands to establish a one-to-one correspondence and attached onto ligand-modified substrates by forming sandwiched complexes. The melting peak and fusion enthalpy of phase change nanoparticles during thermal analysis reflect the type and concentration of biomarkers, respectively. The thermal readout condition can be adjusted in such a way that multiple biomarkers with concentration difference over 3 orders of magnitude have been simultaneously detected under the same condition.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21338061     DOI: 10.1021/ac103102h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Three-dimensional hierarchical plasmonic nano-architecture enhanced surface-enhanced Raman scattering immunosensor for cancer biomarker detection in blood plasma.

Authors:  Ming Li; Scott K Cushing; Jianming Zhang; Savan Suri; Rebecca Evans; William P Petros; Laura F Gibson; Dongling Ma; Yuxin Liu; Nianqiang Wu
Journal:  ACS Nano       Date:  2013-05-14       Impact factor: 15.881

2.  In vitro cytotoxicity of surface modified bismuth nanoparticles.

Authors:  Yang Luo; Chaoming Wang; Yong Qiao; Mainul Hossain; Liyuan Ma; Ming Su
Journal:  J Mater Sci Mater Med       Date:  2012-07-17       Impact factor: 3.896

Review 3.  Phase-Change Materials for Controlled Release and Related Applications.

Authors:  Jichuan Qiu; Da Huo; Younan Xia
Journal:  Adv Mater       Date:  2020-05-08       Impact factor: 30.849

4.  Selective enrichment and sensitive detection of peptide and protein biomarkers in human serum using polymeric reverse micelles and MALDI-MS.

Authors:  Nadnudda Rodthongkum; Rajasekhar Ramireddy; S Thayumanavan; W Vachet Richard
Journal:  Analyst       Date:  2011-12-23       Impact factor: 4.616

Review 5.  Multiplexed detection of molecular biomarkers with phase-change nanoparticles.

Authors:  Ming Su
Journal:  Nanomedicine (Lond)       Date:  2013-02       Impact factor: 5.307

6.  Nanomaterials for Biosensing Applications.

Authors:  Sichao Hou; Aiying Zhang; Ming Su
Journal:  Nanomaterials (Basel)       Date:  2016-03-30       Impact factor: 5.076

Review 7.  Micro- and nano-encapsulated metal and alloy-based phase-change materials for thermal energy storage.

Authors:  Shilei Zhu; Mai Thanh Nguyen; Tetsu Yonezawa
Journal:  Nanoscale Adv       Date:  2021-06-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.