Literature DB >> 21337224

Implementation of asymmetric yielding in case-specific finite element models improves the prediction of femoral fractures.

Loes C Derikx1, Roeland Vis, Timo Meinders, Nico Verdonschot, Esther Tanck.   

Abstract

Although asymmetric yielding in bone is widely shown in experimental studies, previous case-specific non-linear finite element (FE) studies have mainly adopted material behaviour using the Von Mises yield criterion (VMYC), assuming equal bone strength in tension and compression. In this study, it was verified that asymmetric yielding in FE models can be captured using the Drucker-Prager yield criterion (DPYC), and can provide better results than simulations using the VMYC. A sensitivity analysis on parameters defining the DPYC (i.e. the degree of yield asymmetry and the yield stress settings) was performed, focusing on the effect on bone failure. In this study, the implementation of a larger degree of yield asymmetry improved the prediction of the fracture location; variations in the yield stress mainly affected the predicted failure force. We conclude that the implementation of asymmetric yielding in case-specific FE models improves the prediction of femoral bone strength.

Entities:  

Mesh:

Year:  2011        PMID: 21337224     DOI: 10.1080/10255842.2010.542463

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  6 in total

Review 1.  Computed tomography-based finite element analysis to assess fracture risk and osteoporosis treatment.

Authors:  Kazuhiro Imai
Journal:  World J Exp Med       Date:  2015-08-20

2.  Male osteoporosis: A review.

Authors:  Antonio Herrera; Antonio Lobo-Escolar; Jesús Mateo; Jorge Gil; Elena Ibarz; Luis Gracia
Journal:  World J Orthop       Date:  2012-12-18

3.  Calibration with or without phantom for fracture risk prediction in cancer patients with femoral bone metastases using CT-based finite element models.

Authors:  Florieke Eggermont; Nico Verdonschot; Yvette van der Linden; Esther Tanck
Journal:  PLoS One       Date:  2019-07-30       Impact factor: 3.240

4.  The effect of variations in CT scan protocol on femoral finite element failure load assessment using phantomless calibration.

Authors:  Ali Ataei; Jelle Eikhout; Ruud G H van Leeuwen; Esther Tanck; Florieke Eggermont
Journal:  PLoS One       Date:  2022-03-18       Impact factor: 3.240

5.  A mechanical model for predicting the probability of osteoporotic hip fractures based in DXA measurements and finite element simulation.

Authors:  Enrique López; Elena Ibarz; Antonio Herrera; Jesús Mateo; Antonio Lobo-Escolar; Sergio Puértolas; Luis Gracia
Journal:  Biomed Eng Online       Date:  2012-11-14       Impact factor: 2.819

6.  Can patient-specific finite element models better predict fractures in metastatic bone disease than experienced clinicians?: Towards computational modelling in daily clinical practice.

Authors:  F Eggermont; L C Derikx; N Verdonschot; I C M van der Geest; M A A de Jong; A Snyers; Y M van der Linden; E Tanck
Journal:  Bone Joint Res       Date:  2018-07-07       Impact factor: 5.853

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.