Literature DB >> 21336154

Misalignments in the retinal nerve fiber layer evaluation using cirrus high-definition optical coherence tomography.

Javier Moreno-Montañés1, Alfonso Antón, Natalia Olmo, Elvira Bonet, Aurora Alvarez, Jesús Barrio-Barrio, Marta García-Granero, Alicia Gómez-Muñoz.   

Abstract

PURPOSE: To evaluate the frequency and characteristics of misalignments (MAs) in the retinal nerve fiber layer (RNFL) analysis protocol of spectral-domain optical coherence tomography (Cirrus) and determine factors associated with MAs.
METHODS: Three hundred eyes (162 normal and 138 glaucomatous eyes) were included in this cross-sectional study. The MAs were considered limited when they affected only part of the scan line, and complete (CMA) when they were observed in the entire scan line. A subgroup (153 cases) with repeated scans was analyzed to compare the RNFL thicknesses in the scans with and without CMAs.
RESULTS: Two hundred ninety-nine limited MAs were found in 140 eyes (46.7%) and 151 CMAs were found in 91 eyes (30.3%). The frequency and number of CMAs were significantly related to age (P<0.05). Seventy-two CMAs were in the measurement ring in 48 eyes, more frequently in the 3 and 9-o'clock positions (P=0.001) and the horizontal quadrants (P=0.001). Among the repeated scans, the number of cases with CMAs was similar to the first scan (P=0.32). No significant differences were found in global or quadrant RNFL thickness between scans with and without CMAs.
CONCLUSIONS: CMAs were present in the first or second scans in about 30% of cases and were related to older age. CMAs were more frequently in horizontal meridians and quadrants. No differences in RNFL thickness were found between scans with and without CMAs in the same patients. Scans with CMAs in the measurement ring can be considered in the RNFL evaluation.

Entities:  

Mesh:

Year:  2011        PMID: 21336154     DOI: 10.1097/IJG.0b013e3181fa0def

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  10 in total

1.  Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.

Authors:  Ziad Khoueir; Firas Jassim; Linda Yi-Chieh Poon; Edem Tsikata; Geulah S Ben-David; Yingna Liu; Eric Shieh; Ramon Lee; Rong Guo; Georgia Papadogeorgou; Boy Braaf; Huseyin Simavli; Christian Que; Benjamin J Vakoc; Brett E Bouma; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2017-08-12       Impact factor: 5.258

2.  Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.

Authors:  Huseyin Simavli; Linda Yi-Chieh Poon; Christian J Que; Yingna Liu; Mustafa Akduman; Edem Tsikata; Johannes F de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2017-06       Impact factor: 2.503

3.  Enhanced Diagnostic Capability for Glaucoma of 3-Dimensional Versus 2-Dimensional Neuroretinal Rim Parameters Using Spectral Domain Optical Coherence Tomography.

Authors:  Kenneth C Fan; Edem Tsikata; Ziad Khoueir; Huseyin Simavli; Rong Guo; Regina A de Luna; Sumir Pandit; Christian J Que; Johannes F de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2017-05       Impact factor: 2.503

4.  Diagnostic capability of peripapillary retinal thickness in glaucoma using 3D volume scans.

Authors:  Huseyin Simavli; Christian John Que; Mustafa Akduman; Jennifer L Rizzo; Edem Tsikata; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2014-12-09       Impact factor: 5.258

5.  Effects of misalignments in the retinal nerve fiber layer thickness measurements with spectral domain optical coherence tomography.

Authors:  Kleyton A Barella; Fernanda Cremasco; Camila Zangalli; Vital P Costa
Journal:  J Ophthalmol       Date:  2014-12-09       Impact factor: 1.909

6.  Diagnostic accuracy of macular ganglion cell-inner plexiform layer thickness for glaucoma detection in a population-based study: Comparison with optic nerve head imaging parameters.

Authors:  Victor Koh; Yih-Chung Tham; Carol Y Cheung; Baskaran Mani; Tien Yin Wong; Tin Aung; Ching-Yu Cheng
Journal:  PLoS One       Date:  2018-06-26       Impact factor: 3.240

7.  Three-Dimensional Optical Coherence Tomography Imaging For Glaucoma Associated With Boston Keratoprosthesis Type I and II.

Authors:  Ziad Khoueir; Firas Jassim; Boy Braaf; Linda Yi-Chieh Poon; Edem Tsikata; James Chodosh; Claes H Dohlman; Benjamin J Vakoc; Brett E Bouma; Johannes F de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2019-08       Impact factor: 2.503

8.  Effect of image registration on longitudinal analysis of retinal nerve fiber layer thickness of non-human primates using Optical Coherence Tomography (OCT).

Authors:  Shuang Liu; Anjali Datta; Derek Ho; Jordan Dwelle; Daifeng Wang; Thomas E Milner; Henry Grady Rylander; Mia K Markey
Journal:  Eye Vis (Lond)       Date:  2015-02-12

9.  Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography.

Authors:  Elli A Park; Edem Tsikata; Jenny Jyoung Lee; Eric Shieh; Boy Braaf; Benjamin J Vakoc; Brett E Bouma; Johannes F de Boer; Teresa C Chen
Journal:  Transl Vis Sci Technol       Date:  2020-09-10       Impact factor: 3.283

10.  Three-dimensional Neuroretinal Rim Thickness and Visual Fields in Glaucoma: A Broken-stick Model.

Authors:  Wendy W Liu; Michael McClurkin; Edem Tsikata; Pui-Chuen Hui; Tobias Elze; Ali R C Celebi; Ziad Khoueir; Ramon Lee; Eric Shieh; Huseyin Simavli; Christian Que; Rong Guo; Johannes de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2020-10       Impact factor: 2.290

  10 in total