Literature DB >> 21335776

Modification of commercial force feedback hardware for needle insertion simulation.

Timothy R Coles1, Nigel W John, Giuseppe Sofia, Derek A Gould, Darwin G Caldwell.   

Abstract

A SensAble Omni force feedback device has been modified to increase the face validity of a needle insertion simulation. The new end effector uses a real needle hub and shortened needle shaft in place of the Omni's pre-fitted pen shaped end effector. This modification facilitates correct procedural training through the simulation of co-located visual and haptic cues in an augmented reality approach to simulation. The development of the new end effector is described and a pictorial guide to its manufacture and the fitting process is provided. Initial results from face validation studies bode well for the fidelity of this low cost device.

Entities:  

Mesh:

Year:  2011        PMID: 21335776

Source DB:  PubMed          Journal:  Stud Health Technol Inform        ISSN: 0926-9630


  2 in total

1.  Face and content validity of a virtual-reality simulator for myringotomy with tube placement.

Authors:  Caiwen Huang; Horace Cheng; Yves Bureau; Sumit K Agrawal; Hanif M Ladak
Journal:  J Otolaryngol Head Neck Surg       Date:  2015-10-20

Review 2.  Augmented Reality in Emergency Medicine: A Scoping Review.

Authors:  Barbara Shipman; Brendan William Munzer; Mohammad Mairaj Khan; Prashant Mahajan
Journal:  J Med Internet Res       Date:  2019-04-17       Impact factor: 5.428

  2 in total