Literature DB >> 21335331

An audit of diagnostic reference levels in interventional cardiology and radiology: are there differences between academic and non-academic centres?

E T Samara1, A Aroua, R De Palma, J-C Stauffer, S Schmidt, Ph R Trueb, A Stuessi, R Treier, F Bochud, F R Verdun.   

Abstract

A wide variation in patient exposure has been observed in interventional radiology and cardiology. The purpose of this study was to investigate the patient dose from fluoroscopy-guided procedures performed in non-academic centres when compared with academic centres. Four procedures (coronary angiography, percutaneous coronary intervention, angiography of the lower limbs and percutaneous transluminal angioplasty of the lower limbs) were evaluated. Data on the dose-area product, fluoroscopy time and number of images for 1000 procedures were obtained from 23 non-academic centres and compared with data from 5 academic centres. No differences were found for cardiology procedures performed in non-academic centres versus academic ones. However, significantly lower doses were delivered to patients for procedures of the lower limbs when they were performed in non-academic centres. This may be due to more complex procedures performed in the academic centres. Comparison between the centres showed a great variation in the patient dose for these lower limb procedures.

Entities:  

Mesh:

Year:  2011        PMID: 21335331     DOI: 10.1093/rpd/ncq600

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Radiation doses during cardiac catheterisation procedures in India: a multicentre study: Radiation dose study.

Authors:  Vijayakumar Subban; Sophie Amelot; Suma M Victor; Anil Potdar; Vishawanath Yadav; Tejas Patel; Sanjay Shah; Thomas Alexander; Balakumaran Jeyakumaran; Juno Angel; Mullasari S Ajit
Journal:  AsiaIntervention       Date:  2020-07-20

2.  Establishing a diagnostic reference level of radiation dose in coronary angiography and intervention: A prospective evaluation.

Authors:  Vikas Kataria; Ishita Yaduvanshi; Gautam Singal; Mohan Nair
Journal:  Indian Heart J       Date:  2021-09-21

3.  Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals.

Authors:  James A Crowhurst; Mark Whitby; David Thiele; Toni Halligan; Adam Westerink; Suzanne Crown; Jillian Milne
Journal:  J Med Radiat Sci       Date:  2014-08-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.