Literature DB >> 21334186

PVP-coated graphene oxide for selective determination of ochratoxin A via quenching fluorescence of free aptamer.

Linfeng Sheng1, Jiangtao Ren, Yuqing Miao, Jiahai Wang, Erkang Wang.   

Abstract

In this paper, we developed a simple method to detect fungi toxin (ochratoxin A) produced by Aspergillus Ochraceus and Penicillium verrucosumm, utilizing graphene oxide as quencher which can quench the fluorescence of FAM (carboxyfluorescein) attached to toxin-specific aptamer. By optimizing the experimental conditions, we obtained the detection limit of our sensing platform based on bare graphene oxide to be 1.9 μM with a linear detection range from 2 μM to 35 μM. Selectivity of this sensing platform has been carefully investigated; the results showed that this sensor specifically responded to ochratoxin A without interference from other structure analogues (N-acetyl-l-phenylalanine and warfarin) and with only limited interference from ochratoxin B. Experimental data showed that ochratoxin A as well as other structure analogues could adsorb onto the graphene oxide. As compared to the non-protected graphene oxide based biosensor, PVP-protected graphene oxide reveals much lower detection limit (21.8 nM) by two orders of magnitude under the optimized ratio of graphene oxide to PVP concentration. This sensor has also been challenged by testing 1% red wine containing buffer solution spiked with a series of concentration of ochratoxin A.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21334186     DOI: 10.1016/j.bios.2011.01.032

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  33 in total

Review 1.  Biological interactions of graphene-family nanomaterials: an interdisciplinary review.

Authors:  Vanesa C Sanchez; Ashish Jachak; Robert H Hurt; Agnes B Kane
Journal:  Chem Res Toxicol       Date:  2011-10-21       Impact factor: 3.739

Review 2.  Aptamer-based fluorescent biosensors.

Authors:  R E Wang; Y Zhang; J Cai; W Cai; T Gao
Journal:  Curr Med Chem       Date:  2011       Impact factor: 4.530

3.  A Fluorescence Quenching Study of Naphthalimide Dye by Graphene: Mechanism and Thermodynamic Properties.

Authors:  Sanaz Seraj; Shohre Rouhani
Journal:  J Fluoresc       Date:  2017-07-14       Impact factor: 2.217

Review 4.  Graphene/aptamer probes for small molecule detection: from in vitro test to in situ imaging.

Authors:  Yi Dong; Ting Zhang; Xiaoya Lin; Jiangtao Feng; Fang Luo; Hong Gao; Yangping Wu; Ruijie Deng; Qiang He
Journal:  Mikrochim Acta       Date:  2020-02-19       Impact factor: 5.833

5.  A fluorometric aptasensor for patulin based on the use of magnetized graphene oxide and DNase I-assisted target recycling amplification.

Authors:  Liang Ma; Ting Guo; Shuli Pan; Yuhao Zhang
Journal:  Mikrochim Acta       Date:  2018-10-01       Impact factor: 5.833

6.  Recent trends in SELEX technique and its application to food safety monitoring.

Authors:  Jingjing Wu; Yingyue Zhu; Feng Xue; Zhanlong Mei; Li Yao; Xin Wang; Lei Zheng; Jian Liu; Guodong Liu; Chifang Peng; Wei Chen
Journal:  Mikrochim Acta       Date:  2014-04       Impact factor: 5.833

7.  Bio-functionalized graphene-graphene oxide nanocomposite based electrochemical immunosensing.

Authors:  Priyanka Sharma; Satish K Tuteja; Vijayender Bhalla; G Shekhawat; Vinayak P Dravid; C Raman Suri
Journal:  Biosens Bioelectron       Date:  2012-07-21       Impact factor: 10.618

8.  Graphene-Induced Adsorptive and Optical Artifacts During In Vitro Toxicology Assays.

Authors:  Megan A Creighton; J Rene Rangel-Mendez; Jiaxing Huang; Agnes B Kane; Robert H Hurt
Journal:  Small       Date:  2013-06-10       Impact factor: 13.281

9.  A fluorometric aptamer-based assay for ochratoxin A by using exonuclease III-assisted recycling amplification.

Authors:  Mei Liu; Xuanyi Li; Baoxin Li; Jianxiu Du; Zongqi Yang
Journal:  Mikrochim Acta       Date:  2019-12-14       Impact factor: 5.833

10.  Adsorption-desorption nano-aptasensors: fluorescent screening assays for ochratoxin A.

Authors:  Velu Ranganathan; Spencer Boisjoli; Maria C DeRosa
Journal:  RSC Adv       Date:  2022-05-09       Impact factor: 4.036

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.