Literature DB >> 21334142

X-ray phase-contrast tomography of porcine fat and rind.

Torben H Jensen1, Arvid Böttiger, Martin Bech, Irene Zanette, Timm Weitkamp, Simon Rutishauser, Christian David, Elena Reznikova, Jürgen Mohr, Lars Bager Christensen, Eli V Olsen, Robert Feidenhans'l, Franz Pfeiffer.   

Abstract

X-ray computed tomography (CT) has recently received increased attention in the food science community. The aim of this paper is to demonstrate how grating based phase-contrast CT can provide contrast superior to standard absorption based CT. The method of phase-contrast CT is applied to two samples of porcine subcutaneous fat and rind. The additional contrast obtained may be used for quality testing, to investigate variations in fatty acid composition of the fat-fraction, and density variations in the meat-fraction. The possibility of integrating the method into an abattoir environment is discussed.
Copyright © 2011 The American Meat Science Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21334142     DOI: 10.1016/j.meatsci.2011.01.013

Source DB:  PubMed          Journal:  Meat Sci        ISSN: 0309-1740            Impact factor:   5.209


  1 in total

1.  Subcutaneous Low-Density Foreign Bodies Detection via Grating-Based Multimodal X-ray Imaging.

Authors:  Meifang Yin; Mingzhou Yuan; Kai Deng; Jing Li; Guangya Zhang; Jiayuan Zhu; Weiping Xie; Jun Wu
Journal:  J Digit Imaging       Date:  2022-01-21       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.