Multifocal intraocular lens with a surface-embedded near section: Short-term clinical outcomes.

Colm McAlinden1, Jonathan E Moore.   

Abstract

PURPOSE: To evaluate the visual and refractive outcomes and quality of life after implantation of a multifocal intraocular lens (IOL) with a surface-embedded near section.
SETTING: Private practice, United Kingdom.
DESIGN: Case series.
METHODS: This study comprised patients who had implantation of a Lentis Mplus multifocal IOL after phacoemulsification. The main outcome measures were refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities (logMAR), uncorrected (UNVA) and corrected (CNVA) near visual acuities (M notation), reading speed (Radner reading chart), contrast sensitivity (Pelli-Robson), and Quality of Life Impact of Refractive Correction (QIRC) questionnaire scores. A +3.00 diopter (D) reading addition (add) IOL was placed in the nondominant eye and a +1.50 D add IOL in the dominant eye.
RESULTS: The study enrolled 44 eyes of 22 patients (mean age 59.9 years). The mean values 3 months postoperatively were UDVA, 0.04 logMAR ± 0.25 (SD); contrast sensitivity, 1.57 ± 0.13 logCS; near vision, M0.75 ± 0.33 at 32 cm and M0.90 ± 0.27 at 66 cm; reading speed, 161.74 words/minute; sphere, 0.08 ± 0.58 D; astigmatism, -0.60 ± 0.50 D; CDVA, -0.08 ± 0.07 logMAR. With best correction, intermediate (66 cm) and near (32 cm) vision were M0.89 ± 0.26 and M0.74 ± 0.32, respectively. The mean binocular UNVA at the preferred viewing distance was M0.57 ± 0.18, improving to M0.54 ± 0.19 with distance correction. The mean QIRC score improved from 42.15 ± 4.66 to 51.14 ± 8.22.
CONCLUSIONS: Postoperative visual acuity was good with high-level contrast sensitivity, producing significant improvement in quality of life.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21333867     DOI: 10.1016/j.jcrs.2010.08.055

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  20 in total

1.  Optical coherence tomography measurements with the LENTIS Mplus multifocal intraocular lens.

Authors:  Eirini Skiadaresi; Colm McAlinden; Giuseppe Ravalico; Jonathan Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-01-04       Impact factor: 3.117

2.  Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

Authors:  David P Piñero; Vicente J Camps; María L Ramón; Verónica Mateo; Rafael J Pérez-Cambrodí
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

3.  The effect of pupillary dilatation on IOL power measurement by using the IOLMaster.

Authors:  Bharkbhum Khambhiphant; Nattida Chatbunchachai; Krit Pongpirul
Journal:  Int Ophthalmol       Date:  2015-03-26       Impact factor: 2.031

4.  Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification.

Authors:  Peter Žiak; Juraj Halička; Peter Mojžiš; Karolína Kapitánová; Javorka Michal; David P Piñero
Journal:  Int Ophthalmol       Date:  2019-06-05       Impact factor: 2.031

5.  English sentence optotypes for measuring reading acuity and speed--the English version of the Radner Reading Charts.

Authors:  W Radner; G Diendorfer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-06       Impact factor: 3.117

6.  Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.

Authors:  Hungwon Tchah; Kiyeun Nam; Aeri Yoo
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

7.  Impact of contact lens zone geometry and ocular optics on bifocal retinal image quality.

Authors:  Arthur Bradley; Jayoung Nam; Renfeng Xu; Leslie Harman; Larry Thibos
Journal:  Ophthalmic Physiol Opt       Date:  2014-03-04       Impact factor: 3.117

8.  [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

Authors:  B C Thomas; G U Auffarth; R Philips; J Novák; J Blazek; H Adamkova; T M Rabsilber
Journal:  Ophthalmologe       Date:  2013-11       Impact factor: 1.059

9.  Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract.

Authors:  Colm McAlinden; Qinmei Wang; Konrad Pesudovs; Xin Yang; Fangjun Bao; Ayong Yu; Shishi Lin; Yifan Feng; Jinhai Huang
Journal:  PLoS One       Date:  2015-06-10       Impact factor: 3.240

Review 10.  The evolution of corneal and refractive surgery with the femtosecond laser.

Authors:  Antonis Aristeidou; Elise V Taniguchi; Michael Tsatsos; Rodrigo Muller; Colm McAlinden; Roberto Pineda; Eleftherios I Paschalis
Journal:  Eye Vis (Lond)       Date:  2015-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.