Comparative study of condylar settings of three semiadjustable articulators.

M Gross1, C Nemcovsky, L D Friedlander.   

Abstract

The reproducibility of arcon semiadjustable Whip Mix, Denar Mark II, and Hanau 158 articulators was tested using multiple protrusive and lateral edge-to-edge wax interarch registrations made with an interocclusal device. Photographic and cephalometric tracings verified an identical angulation between the axis-orbital craniofacial reference plane and the maxillary occlusal plane for the subject and both the Denar Mark II and Hanau 158 articulators. This angle was 2.5 degrees less in the Whip Mix instrument. Three operators made three settings for each of 12 protrusive and 24 lateral interarch registrations for each articulator. Results showed significant differences between instruments. Whip Mix consistently gave the highest.angulations and Hanau 158 the lowest. For protrusive records there was no significant difference between examiners, but for lateral records a significant difference in examiner registration was found. For both protrusive and nonworking registrations, interaction was seen between instrument and operator and between instrument and registration, and a significant difference was seen between records. This study supports previous studies showing that semiadjustable articulators using interarch records have a low level of reproducibility and are subject to variables of instrument, operator, and occlusal records.

Entities:  

Mesh:

Year:  1990        PMID: 2133380

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  A comparative study to measure the condylar guidance by the radiographic and clinical methods.

Authors:  Pragya Shreshta; Veena Jain; Ashu Bhalla; Gunjan Pruthi
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

2.  An in vitro study to evaluate the accuracy of orthopantomograph as an aid to determine condylar guidance.

Authors:  Sukhjit Kaur; Kusum Datta
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

3.  Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods.

Authors:  Oh-Kyun Kwon; Seung-Won Yang; Jee-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

4.  A comparative study to correlate between clinically and radiographically determined sagittal condylar guidance in participants with different skeletal relationships.

Authors:  Sweta Singh; Samiran Das; Jayanta Bhattacharyya; Soumitra Ghosh; Preeti Goel; Kaushik Dutta
Journal:  J Indian Prosthodont Soc       Date:  2017 Apr-Jun

5.  A study on the accuracy of horizontal condylar guidance values in edentulous patients using preprosthetic diagnostic radiographs.

Authors:  Rahul Paul; Samiran Das; Jayanta Bhattacharyya; Soumitra Ghosh; Preeti Goel; Kaushik Dutta
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

6.  Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study.

Authors:  S R Keerthana; H S Mohammed; A Hariprasad; M Anand; Syeda Ayesha
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.